The Raid Controller Module; Controller Module Interfaces - Bosch DVA-16K SCSI Installation Manual

Raid subsystem scsi premium series
Hide thumbs Also See for DVA-16K SCSI:
Table of Contents

Advertisement

14
en | Introduction
2.5.3

The RAID Controller Module

The RAID controller module contains a main circuit board, a preinstalled 256MB capacity or
above DDR RAM DIMM module and the controller module interfaces. The controller module
contains no user-serviceable components. Except when installing/upgrading the cache mem-
ory inside, the controller module should never be removed or opened.
CAUTION!
Although the RAID controller can be removed, the only time you should touch the controller
itself is to install the memory modules. The RAID controller is built of sensitive components
and unnecessary tampering can damage the controller.
The heart of the RAID controller subsystem is the 320MB per second SCSI-to-SATA controller
board. The controller comes with two (2) pre-set SCSI-320 host channels, CH0 and CH1. The
subsystem connects to the host through a VHDCI SCSI input connector, while the output con-
nector is ready to connect external devices. (See Figure 2.9)
The docking connector at the rear of the controller board is used to connect the controller
module to the backplane board. A DDR RAM DIMM socket is strategically placed in an easily
accessible location on the controller board for easy insertion of the DDR RAM DIMM module.
2.5.4

Controller Module Interfaces

All external interfaces that connect to external devices are located on the controller module
rear panel shown in Figure 2.9. The interfaces are listed below.
Fig. 2.9 Controller Module Interfaces
F.01U.027.799 | V2 | 2008.08
Host Ports: Two (2) SCSI-320 host channels (CH0 and CH1 in Figure 2.9) connect the
subsystem to the host through two (2) dual-stacked VHDCI SCSI connectors.
Ethernet Ports: A single 10/100BaseT Ethernet port (located next to COM2) is used for
remote management through the network.
COM ports: The controller module comes with two (2) COM ports. One port is used to
access the controller-embedded configuration utility through the network, and the other
connects to a UPS connection. .
Levers: Two (2) levers located in the sides of the controller board rear panel provide easy
controller module installation and secure the controller module in place.
RAID Subsystem DVA-16K | Installation Manual
Bosch Security System

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dva-16k series

Table of Contents