TAPING UP THE WIRE/TUBES/HOSE

After running the wire, hose and tubing outside, tape them up as shown below to insulate.
1. Tape the two copper tubes, drain hose (and the
electrical wiring if local codes permit) together with
the supplied tape. Make sure the electrical wiring
does not come in direct contact with the copper tub-
ing or drain hose. Approximately 1 foot outside the
hole, let the drain hose out and separate from the
copper tubing and wiring.
Wall braket
Connecting
cable
3. Wrap the piping joints with the insulator plate and fas-
ten it with vinyl tape.
pipe

APPLYING PUTTY AND INSERTING WALL CAP

After running the wires and tubing outside, putty should be inserted around the opening on the outside to protect against
rain, wind, etc. To apply putty, see below:
1. Apply the putty to any area on the outside hole that air
or rain can get into.
Apply Putty
Here
Tubing
Introduceti chit
Drain hose
1/2" side piping
1/4" side piping
Drain Hose
insulator plete
vinyl tape
2. Begin wrapping from the point the tubing comes out of
the outdoor unit and continue to the hole in the wall.
Leave no gaps or breaks and cover the entire length
of the tubing. As you wrap, overlap the previous turn
by half the width of the tape.
4. After wrapping the connection pipe with tape, fasten it
to the outside wall with saddles, etc.
Wall cap
Saddle
(Not supplied)
2. After applying putty, insert the wall Cap at Indoor side
and Outdoor side.
Wall Bracket
Wall Cap
(For DS-110R)
Indoor side
11
Pipe
Tape
Insert Putty
Drain Hose
Wall
Outdoor side