Daewoo DSB-075LH User Manual

Daewoo DSB-075LH User Manual

Split-type room air conditioner
Hide thumbs Also See for DSB-075LH:

Advertisement

USE'S MANUAL
SPLIT-TYPE ROOM AIR CONDITIONER
MODEL #:
DSB-075LH
DSB-095LH
DSB-125LH
DSB-185LH
Please read the operating instructions and safety
precautions carefully and thoroughly before installing
and operating your room air conditioner.
S1

Advertisement

Table of Contents
loading

Summary of Contents for Daewoo DSB-075LH

  • Page 1 USE'S MANUAL SPLIT-TYPE ROOM AIR CONDITIONER MODEL #: DSB-075LH DSB-095LH DSB-125LH DSB-185LH Please read the operating instructions and safety precautions carefully and thoroughly before installing and operating your room air conditioner.
  • Page 2: Table Of Contents

    CONTENTS SAFETY PRECAUTIONS ..................PARTS NAMES ..................... MANUAL OPERATION ..................OPTIMAL OPERATION ..................ADJUSTING AIR FLOW DIRECTION..............HOW THE AIR CONDITIONER WORKS..............MAINTENANCE....................... OPERATION TIPS ....................TROUBLESHOOTING TIPS................... Read This Manual Inside you will find many helpful hints on how to use and maintain your air conditioner properly.
  • Page 3: Safety Precautions

    Safety Precautions To prevent injury to the user or other people and property damage, the following instructions must be followed. Incorrect operation due to ignoring of instructions may cause harm or damage. The seriousness is classified by the following indications. WARNING This symbol indicates the possibility of death or serious injury.
  • Page 4 ! CAUTION When the air filter is to be Do not clean the air Ventilate the room well when removed, do not touch the conditioner with water. used together with a stove, etc. metal parts of the unit. It may cause an injury. Water may enter the unit and An oxygen shortage may occur.
  • Page 5 Prior to Operation 1. Contact an installation specialist for installation. 2. Make sure the unit is grounded efficiently. 3. Do not use a damaged or non-standard power cord. 4. Do not share the same outlet with other appliances. 5. Do not use an extension cord. 6.
  • Page 6: Parts Names

    PARTS NAMES Indoor unit Indoor unit 1. Front panel 2. Air inlet 3. Air filter 4. Air outlet Horizontal air flow grille Vertical air flow louver 7. Display panel 8. Remote controller signal receiver 9. Remote controller 10. Manual control button Outdoor unit 11.
  • Page 7: Manual Operation

    MANUAL OPERATION Manul operation can be used temporarily in case you can not find the remote controller or its batteries are exhausted. Open and lift the front panel up to an angle until it remains fixed with a clicking sound. One press of the manual control button will lead to the forced AUTO operation.
  • Page 8: Adjusting Air Flow Direction

    ADJUSTING AIR FLOW DIRECTION Adjust the air flow direction properly otherwise, it might cause discomfort or cause uneven room temperatures. Adjust the horizontal louver using the remote controller. Adjust the vertical louver manually. Adjusting the Vertical Air Flow Direction (up - down) The air conditioner automatically adjusts the vertical air flow direction in accordance with the operating mode.
  • Page 9: How The Air Conditioner Works

    CAUTION The AIR DIRECTION and SWING buttons will be disabled when the air conditioner is not in operation (including when the TIMER is set). Do not operate the air conditioner for long periods with the air flow direction set downward in cooling or dry mode.
  • Page 10: Maintenance

    MAINTENANCE WARNING It is necessary to stop the air conditioner and dis- Household connect the power supply before cleaning. Drain Cleaner Cleaning the indoor unit and remote controller CAUTIONS Use a dry cloth to wipe the indoor unit and remote controller.
  • Page 11 4. Remove the Electrostatic Filter from its support frame as shown in the Figure on the left (Not applicable to the units without electrostatic filter). Do not touch this Electrostatic Filter within 10 minutes after opening the inlet grille, it may Electrostatic Filter cause an electric shock.
  • Page 12: Operation Tips

    OPERATION TIPS The following events may occur during normal operation. Protection of the air conditioner. Compressor protection The compressor can't restart for 3 minutes after it stops. Anti-cold air (Cooling and heating models only) The unit is designed not to blow cold air on HEAT mode, when the indoor heat exchanger is in one of the following three situations and the set temperature has not been reached.
  • Page 13 7. Dripping water may generate on the surface of the indoor unit when cooling in a high relatively humidity (relative humidity higher than 80%). Adjust the horizontal louver to the maximum air outlet position and select HIGH fan speed. Heating mode (For cooling and heating models only) The air conditioner draws in heat from the outdoor unit and releases it via the indoor unit during heating operation.
  • Page 14: Troubleshooting Tips

    Troubleshooting tips Malfunctions and Solutions Stop the air conditioner immediately if one of the following faults occur. Disconnect the power and contact the nearest customer service center. OPERATION indicator or other indicators flash rapidly(5 times every second) and this flash cannot be fixed by disconnecting the power, and then connect it again. Trouble Fuse blows frequently or circuit breaker trips frequently.
  • Page 15 ABOUT THIS MANUAL ABOUT THIS MANUAL...

This manual is also suitable for:

Dsb-095lhDsb-125lhDsb-185lh

Table of Contents