WI1093C 3/04
KEYPAD CONFIGURATION MODE
Note: Default configuration shown for GEM-K1CA Keypad.
GEM-RP1CAe2/GEM-K1CA
Move Jumper JP5 * from Pins 1-2 to Pins 2-3
(Wait about 15 seconds: "01 OUT OF SYSTEM")
Enter Factory Code:
11123
Press
Keypad Beep ON/OFF
Entry Sounder
Keypad Address 01
New Compat# 0000 **
EZM Address 00
Zone Response 00
Program Control Message# 1
Press
("01 OUT OF SYSTEM")
Return Jumper JP5 * from Pins 2-3 to Pins 1-2
* JP5 is located at the top-right corner of the circuit board.
** If a Compatibility Number other than "0000" is programmed, "OLD COMPAT# XXXX" is displayed.