NAPCO Gemini GEM-P1632 Installation Instructions Manual page 42

Control panel/communicator
Table of Contents

Advertisement

!
Page 42
WI808F 8/03
Two-Digit Format See Data Format
Two-Wire Smoke Detectors See Smoke Detectors
User Codes/Area 1 & 2 Options; User Closing and Opening Reports by Telephone Numbers; Enable User Code by Area
Up to 32 six-digit User Codes are programmable, each with its dedicated Area 1 & Area 2 Options. (Disabled, Arm/Disarm, Arm Only,
Service, Access, Ambush and User Program). Refer to Easy Menu Driven Program Mode. If reporting to a central station, program
User Closing and Opening Reports by Telephone Numbers (Address 0440-0459). Note: An Ambush Code should not contain digits
used as the first two digits of any user code. Note: Duplicate User Codes are not allowed.
Veri-Phone™ Audio Priority Over Alarms; Veri-Phone Zones Trip PGM2 Output
If Silence All Outputs During Audio Session is selected, all output relays will turn off whenever an active low is applied to control-panel
Lug E19 (Listen In). Connect Veri-Phone Terminal 16 (INHO) to Lug E19. Note: Do not program Keypad Sounder on Alarm for Listen-
In Zones.
If "Veri-Phone Audio Priority Over Alarms" (Address 0722) is programmed and an active low is applied to the panel's Listen-In Lug
(E19), any subsequent alarm reports (except fire alarms) generated during an audio session will be delayed until the end of the
session. (Whenever a listen-in session is in progress, the Veri-Phone will output an active low at its INHO Terminal (16) and Lug E1.)
Program "Veri-Phone Zones Trip PGM2 Output" (Address 0722) to have selectable Listen-In Zones. Connect Veri-Phone Terminal 13
(TRIGL) to control-panel Terminal 8 (PGM2). Program the zone or event for PGM2. Do not use the PGM2 for any other purpose.
Zone ANDing, Groups 1–4 (Not for UL installations); Enable Local Alarm on First Zone "AND" Trip (Not for UL installations)
Up to four groups of at least two zones each can be "AND"ed (Address 0534-0537, 0589-0592, 0644-0647, 0699-0702), wherein the
system will go into alarm only if any two zones of the group are tripped within one minute. This feature is designed to afford redundant
protection for devices, such as glass break detectors, PIRs, etc., that may show a tendency to false under certain conditions. Program
each Group for any number of Zones available. All Zones in any Group must be within the same Area. Do not mix 24-Hour Zones and
non-24-Hour Zones within the same Group. Do not include a Panic Zone as part of any Group. Auto-Reset must be programmed for
each Zone ANDing Zone. Note: Any zone that is bypassed or goes into Swinger Shutdown will automatically disable Zone Anding for
the entire Group. If "Enable Local Alarm on First ZoneAND Trip" (Address 0719) is programmed, a trip on any Zone of the Group will
cause an alarm output and alarm display at the keypad; there will be no communication to the central station. Note: If "Enable CP-01
Limits" is enabled in EZ Programming, any Zone in a Group will only activate an alarm and send a report ONCE. After the Zone has
reported, it will remain in the Group and may still initiate the Zone ANDing sequence.
Zone Area 1–Zone Area 2 See Areas
Zone Number on Pulse Alarm See Data Formats: Two-Digit Format
Zone Status
In high security installations where Disable Auto Status has been programmed, enter the User code and press
until "Display
R
Zone Status Y/N" is displayed. Press NEXT/YES and then NEXT/PRIOR to scroll through any faulted zones.
Zone Type See Central Station Receiver Data Formats: Modem Formats
2-Wire, 4-Wire Smoke Detectors See Smoke Detectors
24-Hour Zone
A zone selected for "24-Hour Zone" (Address 0499, 0554, 0609, 0664) that provides protection at all times, whether or not the system
is armed. If "Alarm Output", "Pulsed Alarm Output", "PGM1 Output", "PGM2 Output" and "Keypad Sounder on Alarm" are not selected,
then the zone is programmed for silent alarm. In this case, there will be no indication on the keypad if the zone is tripped. A 24-Hour
Zone will be reset when the zone fault has been cleared and the area has been armed and disarmed. Note: Do not program a Day
Zone as a 24-Hour Zone.