1. Make sure that the power cord is unplugged.
Place a piece of cardboard below the rear of the
Frame (57) to protect the floor or carpet.
Attach the Left Wheel Cap (92) to the Base (91)
with two #8 x 3/4" Screws (2).
Attach the Right Wheel Cap (not shown) to
the right side of the Base (91) in the same
way.
2. Pull the Upright Wire (77) and the ground wire
(A) through the indicated hole in the Base (91).
Attach the ground wire (A) to the Base (91) with
a #8 x 1/2" Ground Screw (10).
Press the Grommet (75) into the square hole in
the Base (91).
3. Identify the Left Upright (88), which is marked
"Left." Have a second person hold the Left
Upright near the Base (91).
See the inset drawing. Tie the wire tie in the
Left Upright (88) securely around the Upright
Wire (77) about 8 in. (20 cm) down from the end.
Then, pull the other end of the wire tie until the
Upright Wire is routed through the Left Upright.
Note: The Upright Wire should bend so that the
connectors are pointing downward.
1
91
2
2
Hole
77
10
3
77
Wire
Tie
88
7
57
92
Cardboard
75
A
91
Wire Tie
88
77
91
77