Summary of Contents for Fluke 717-10000G

  • Page 1 700G Series Pressure Gauge Users Manual November 2011 © 2011 Fluke Corporation. All rights reserved. Specifications are subject to change without notice. All product names are trademarks of their respective companies. MyFlukeStore 1.877.766.5412 www. .com Shop for Fluke products online at:...
  • Page 2 LIMITED WARRANTY AND LIMITATION OF LIABILITY This Fluke product will be free from defects in material and workmanship for three years from the date of purchase. This warranty does not cover fuses, disposable batteries, or damage from accident, neglect, misuse, alteration, contamination, or abnormal conditions of operation or handling.
  • Page 3: Table Of Contents

    Table of Contents Title Page Introduction ........................1 How to Contact Fluke ..................... 1 Standard Equipment....................... 2 Safety Information ......................2 Hazard Location Information/Approvals ..............3 Special Conditions for Safe Use ................3 Symbols ........................4 Display and Buttons ....................... 5 Operation ........................
  • Page 4 RS-232 Interface ....................... 11 Specifications ........................ 12 Available Input Ranges ..................... 12 Accuracy ........................12 Media Compatibility ....................12 Environmental ......................12 Mechanical Specifications ..................13 PI Ranges and Resolution ..................14 MyFlukeStore 1.877.766.5412 www. .com Shop for Fluke products online at:...
  • Page 5: List Of Tables

    List of Tables Table Title Page Symbols ..........................4 Display and Buttons ......................5 MyFlukeStore 1.877.766.5412 www. .com Shop for Fluke products online at:...
  • Page 6 700G Series Users Manual MyFlukeStore 1.877.766.5412 www. .com Shop for Fluke products online at:...
  • Page 7: List Of Figures

    List of Figures Figure Title Page The Product ........................... 5 Change the Batteries ......................10 MyFlukeStore 1.877.766.5412 www. .com Shop for Fluke products online at:...
  • Page 8 700G Series Users Manual MyFlukeStore 1.877.766.5412 www. .com Shop for Fluke products online at:...
  • Page 9: Introduction

    Introduction How to Contact Fluke The 700G Series Pressure Gauges (the Product) are To contact Fluke, call one of the following telephone high-accuracy digital pressure test gauges. Accurate to numbers: 0.05 % FS, the Products can be used as a calibration...
  • Page 10: Standard Equipment

    Product. Replace the batteries when the low battery indicator ()shows to prevent incorrect measurements. Do not use and disable the Product if it is damaged. MyFlukeStore 1.877.766.5412 www. .com Shop for Fluke products online at:...
  • Page 11: Hazard Location Information/Approvals

    These areas are also any damage that can cause a safety concern. If referred to as hazardous locations, see NFPA 70 Article necessary, return the Product for evaluation to Fluke. 500. Refer to the How to Contact Fluke section.
  • Page 12: Symbols

    Conforms to relevant North American Hazardous voltage. Risk of electrical shock. Safety Standards. Do not dispose of this product as Pressure unsorted municipal waste. Go to Fluke’s website for recycling information.  Conforms to relevant Australian standards. Conforms to ATEX requirements MyFlukeStore 1.877.766.5412...
  • Page 13: Display And Buttons

    To clear the MIN MAX memory values, push and hold  for 2 seconds until CLr is shown. In Configure Mode, push  () to move backward through the menus. gsn001.eps Figure 1. The Product MyFlukeStore 1.877.766.5412 www. .com Shop for Fluke products online at:...
  • Page 14: Operation

    Pressure now shows in the chosen engineering units. See the Specifications section for a list of available engineering units. See the Supervisory Mode section for instructions to set up custom units. MyFlukeStore 1.877.766.5412 www. .com Shop for Fluke products online at:...
  • Page 15: Set Auto Off

    Selections are “on”  and “off” . Damping smooths of the tare position. This is done to make sure that even readings from pulsating pressure sources. with a “0” reading pressure is being applied to the gauge. MyFlukeStore 1.877.766.5412 www. .com Shop for Fluke products online at:...
  • Page 16: Function Lock

    1. The password is factory set and cannot be changed. Push . From this point each parameter can be locked or unlocked. Push  and  to select UnLOC or LOC for MyFlukeStore 1.877.766.5412 www. .com Shop for Fluke products online at:...
  • Page 17: How To Set A Custom Engineering Unit Or Scale

    How to Change the Batteries section. is not used for an extended period. Be sure that the battery polarity is correct to prevent battery leakage. Have an approved technician repair the Product. MyFlukeStore 1.877.766.5412 www. .com Shop for Fluke products online at:...
  • Page 18: How To Change The Batteries

    Use a Phillips screwdriver to loosen the captive screw on the battery door. Remove the battery door. Replace the three AA batteries. Install the battery door again. Tighten the captive screw. gsn002.eps Figure 2. Change the Batteries MyFlukeStore 1.877.766.5412 www. .com Shop for Fluke products online at:...
  • Page 19: Accessories

    700G/TRACK Software. For specifications on the interface, see the Specifications section. XWWarning To prevent possible electrical shock, fire, or personal injury, do not use the RS-232 interface in hazardous areas. MyFlukeStore 1.877.766.5412 www. .com Shop for Fluke products online at:...
  • Page 20: Specifications

    Storage ..................-20 °C to +70 °C (-4 °F to +158 °F) Humidity ..................10 % to 95 % RH Non-condensing Pollution Degree ................2 Agency Approvals ................P, , ) ( MyFlukeStore 1.877.766.5412 www. .com Shop for Fluke products online at:...
  • Page 21: Mechanical Specifications

    20-Segment bar graph, 0 to 100 % Power Battery ................... three size AA alkaline batteries Battery Life ................1,500 hours without backlight (continuous on), 2,000 hours at slow sample rate MyFlukeStore 1.877.766.5412 www. .com Shop for Fluke products online at:...
  • Page 22: Pi Ranges And Resolution

    344.74 689.48 mbar 68.94757 1034.2 2068.4 6894.8 20684 34474 68948 6.894757 103.42 206.84 689.48 2068.4 3447.4 6894.8 20684 34474 68948 0.006894757 0.1034 0.2068 0.6895 2.0684 3.4474 6.8948 20.684 34.474 68.948 MyFlukeStore 1.877.766.5412 www. .com Shop for Fluke products online at:...
  • Page 23 27.68067 415.21 830.42 2768.1 8304.2 13840 27681 83042 inH2O @ 20°C 27.72977 415.95 831.89 2773.0 8318.9 13865 27730 83189 inH2O @ 60°F 27.70759 415.61 831.23 2770.8 8312.3 13854 27708 83123 MyFlukeStore 1.877.766.5412 www. .com Shop for Fluke products online at:...
  • Page 24 33.708 67.416 224.72 674.16 1123.6 2247.2 6741.6 11236 22472 m Sea Water 0.68494382 10.274 20.548 68.494 205.48 342.47 684.94 2054.8 3424.7 6849.4 Torr 51.71507 775.73 1551.5 5171.5 15515 25858 51715 MyFlukeStore 1.877.766.5412 www. .com Shop for Fluke products online at:...

This manual is also suitable for:

717-15g700g series