Download Print this page

Fluke 700P00 Reference

Pressure module

Advertisement

Quick Links

Pressure module specifications
Range/
Model
Resolution
Differential
FLUKE-700P00
1 in. H
O/0.001
2
FLUKE-700P01
10 in. H
O/0.01
2
FLUKE-700P02
1 psi/0.0001
FLUKE-700P22
1 psi/0.0001
FLUKE-700P03
5 psi/0.0001
FLUKE-700P23
5 psi/0.0001
FLUKE-700P04
15 psi/0.001
FLUKE-700P24
15 psi/0.001
Gage
FLUKE-700P05
30 psi/0.001
FLUKE-700P06
100 psi/0.01
FLUKE-700P27
300 psi / 0.01
FLUKE-700P07
500 psi/0.01
FLUKE-700P08
1000 psi/0.1
FLUKE-700P09
1500 psi/0.1
Absolute (not compatible with Fluke 701 or 702)
FLUKE-700PA3
5 psi/0.0001
FLUKE-700PA4
15 psi/0.001
FLUKE-700PA5
30 psi/0.001
FLUKE-700PA6
100 psi/0.01
Vacuum (not compatible with Fluke 701 or 702)
FLUKE-700PV3
-5 psi/0.0001
FLUKE-700PV4
-15 psi/0.001
Dual
FLUKE-700PD2 ±1 psi/0.0001
FLUKE-700PD3 ±5 psi/0.0001
FLUKE-700PD4 ±15 psi/0.001
FLUKE-700PD5 -15/30 psi/0.001 -100/207 kPa/0.01
FLUKE-700PD6 -15/100 psi/0.01 -100/690 kPa/0.07
FLUKE-700PD7 -15/200 psi/0.01 -100/1380 kPa/0.1
High
FLUKE-700P29
3000 psi/0.1
FLUKE-700P30
5000 psi/0.1
FLUKE-700P31
10000 psi/1
(all specifications in % of full span. Specifications reflect a confidence interval of 95%.)
Reference
Range (approx)/
uncertainty
Stability
Resolution
(23 ± 3ºC)
0.25 kPa/0.0002
0.300
2.5 kPa/0.002
0.200
6900 Pa/0.7
0.150
6900 Pa/0.7
0.100
34 kPa/0.001
0.050
34 kPa/0.001
0.025
103 kPa/0.01
0.025
103 kPa/0.01
0.025
207 kPa/0.01
0.025
690 kPa/0.07
0.025
2070 kPa / 0.1
0.025
3400 kPa/0.1
0.025
6900 kPa/0.7
0.025
10 MPa/0.001
0.025
34 kPa/0.001
0.050
103 kPa/0.01
0.050
207 kPa/0.01
0.050
690 kPa/0.07
0.050
-34 kPa/0.001
0.040
-103 kPa/0.01
0.040
±6900 Pa/0.7
0.150
±34 kPa/0.001
0.040
±103 kPa/0.01
0.025
0.025
0.025
0.040
20.7 M Pa/0.001
0.050
34 M Pa/0.001
0.050
69 M Pa/0.007
0.050
Temperature
Total
1
(1 year)
(0 to 50ºC)
uncertainty media
0.025
0.025
0.350
0.050
0.050
0.300
0.070
0.080
0.300
0.020
0.030
0.150
0.020
0.030
0.100
0.010
0.015
0.050
0.010
0.015
0.050
0.010
0.015
0.050
0.010
0.015
0.050
0.010
0.015
0.050
0.010
0.015
0.050
0.010
0.015
0.050
0.010
0.015
0.050
0.010
0.015
0.050
0.010
0.010
0.070
0.010
0.010
0.070
0.010
0.010
0.070
0.010
0.010
0.070
0.015
0.015
0.070
0.015
0.015
0.070
0.025
0.025
0.200
0.015
0.015
0.070
0.010
0.015
0.050
0.010
0.015
0.050
0.010
0.015
0.050
0.015
0.015
0.070
0.010
0.020
0.080
0.010
0.020
0.080
0.010
0.020
0.080
High
Low
Max over-
2
2
side
side
Fitting
pressure
media
material (x nominal)
Dry
Dry
316 SS
30x
Dry
Dry
316 SS
3x
Dry
Dry
316 SS
3x
316 SS
Dry
316 SS
Dry
Dry
316 SS
3x
316 SS
Dry
316 SS
Dry
Dry
316 SS
3x
316 SS
Dry
316 SS
316 SS
N/A
316 SS
316 SS
N/A
316 SS
316 SS
N/A
316 SS
316 SS
N/A
316 SS
316 SS
N/A
316 SS
316 SS
N/A
316 SS
316 SS
N/A
316 SS
316 SS
N/A
316 SS
316 SS
N/A
316 SS
316 SS
N/A
316 SS
316 SS
Dry
316 SS
3x
316 SS
Dry
316 SS
3x
316 SS
Dry
316 SS
3x
316 SS
Dry
316 SS
3x
316 SS
Dry
316 SS
3x
316 SS
N/A
316 SS
3x
316 SS
N/A
316 SS
3x
316 SS
N/A
316 SS
3x
C276
N/A
C276
C276
N/A
C276
C276
N/A
C276
1.5x
Total uncertainty, one
1
year for temperature
range 0°C to +50°C. Total
3x
uncertainty, 1.0% of full
span for temperature
range -10°C to 0°C.
3x
For P00 module only,
compensated
3x
temperature range is
15° to 35° C.
"Dry" indicates dry air
2
3x
or non-corrosive gas as
3x
compatible media.
"316 SS" indicates media
3x
compatible with Type
3x
316 Stainless Steel.
3x
"C276" indicates media
2x
compatible with
Hastelloy C276.
Use of pressure zero is
3x
required prior to
3x
measurement or source.
Maximum overpressure
3x
specification includes
3x
common mode pressure.
Modules are
rated.
Metric adapter(s):
1/4" NPT female to male
BSP/ISO 1/4-19, tapered
thread, included with all
modules except P29,
P30, and P31. Effective
October 1996, all
modules include a NIST
traceable certificate and
test data.
2x
2x

Advertisement

loading

This manual is also suitable for:

700p03700p04700p01700p05700p05ex700p06 ... Show all