Download Print this page
Fluke 381 Specifications

Fluke 381 Specifications

Fluke 381 remote display true-rms ac/dc clamp meter with iflex
Hide thumbs Also See for 381:

Advertisement

Quick Links

381 Remote Display True-rms
AC/DC Clamp Meter with iFlex
The first clamp meter with a detachable, remote
display for easier, faster, safer measurements
The new Fluke 381 does everything you would expect from a
clamp meter, and then lets you remove the display for even more
flexibility. Now one technician can do jobs that used to require
two people; clamp the Fluke 381 around a conductor, remove the
display and walk across the room to operate controls or remove
protective equipment, all while watching real-time readings. The
new iFlex
flexible current probe (included) expands the mea-
surement range to 2500 A ac while providing increased display
flexibility, ability to measure awkward sized conductors and
improved wire access.

Technical Data

Measurement capability
• 1000 A ac and dc current
measurement with fixed jaw
• 2500 A ac current measure-
ment with iFlex
current probe
• 1000 V ac and dc voltage
measurement
• True-rms ac voltage and
current for accurate measure-
ments on non-linear signals
• Frequency measurement to
500 Hz with both jaw and
iFlex
• 60 kΩ resistance mea-
surement with continuity
detection
• Min, max, average and inrush
recording to capture varia-
tions automatically
Features
• Wireless technology allows
the display to be carried up to
30 ft away from the point of
measurement for added flex-
ibility without interference
with measurement accuracy
• iFlex
expands the measurement
range to 2500 A ac while
providing increased display
flexibility, ability to measure
awkward sized conductors
and improved wire access
• CAT IV 600V, CAT III 1000 V
safety rating
• Integrated low pass filter
and state of the art signal
processing allows for use
in noisy electrical environ-
®
C
US
ments while providing stable
readings
flexible
flexible current probe

Advertisement

loading
Need help?

Need help?

Do you have a question about the 381 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Fluke 381

  • Page 1: Technical Data

    The first clamp meter with a detachable, remote display for easier, faster, safer measurements Technical Data The new Fluke 381 does everything you would expect from a Measurement capability clamp meter, and then lets you remove the display for even more •...
  • Page 2 • Proprietary inrush measure- Specifications ment technology to filter Fluke 381 Range Resolution Accuracy out noise and capture motor starting current exactly as the AC current via jaw 999.9 A 0.1 A 2 % ± 5 digits circuit protection sees it AC current via iFlex 2500 A 0.1 A 3 % ± 5 digits • Ergonomic design fits in your ™ hand and can be used while DC current 999.9 A 0.1 A 2 % ± 5 digits wearing personal protective 1000 V 0.1 V 1.5 % ± 5 digits...