Download Print this page

Specifications; Ordering Information; General Specifications - Fluke 287 Specifications

Fluke 287 true-rms electronics logging multimeter with trendcapture
Hide thumbs Also See for 287:

Advertisement

Specifications

Function
Range and Resolution
DC volts
50.000 mV,500.00 mV, 5.0000 V, 50.000 V,
AC volts
500.00 V, 1000.0 V
DC current
500.00 µA, 5000.0 µA, 50.000 mA, 400.00 mA,
AC current
5.0000 A, 10.000 A
Temperature
-200.0 °C to 1090.0 °C (-328.0 °F to 1994.0 °F)
(excluding probe)
Resistance
500.00 Ω, 5.0000 kΩ, 50.000 kΩ, 500.00 kΩ, 5.0000
MΩ, 50.00 MΩ, 500.0 MΩ
Capacitance
1.000 nF,10.00 nF 100.0 nF, 1.000 µF, 10.00 µF,
100.0 µF, 1000 µF, 10.00 mF, 100 mF
Frequency
99.999 Hz, 999.99 Hz, 9.9999 kHz, 99.999 kHz,
999.99 kHz
Additional Functions/Features
Multiple on screen displays
True-rms ac bandwidth
dBV/dBm
DC mV resolution
Megohm range
Conductance
Continuity beeper
Battery/fuse access
Elapse time clock
Time of day clock
Min-max-avg
Peak
Duty cycle
Pulse width
Hold
Isolated optical interface
Auto/touch hold
Reading memory
Log to PC
Interval/event logging
Logging memory
General
specifications
Maximum voltage between any
terminal and earth ground:
1000 V
Battery type: 6 AA alkaline bat-
teries, NEDA 15A IEC LR6
Battery life: 50 hours minimum,
180 hours in logging mode
Temperature:
Operating: -20 °C to 55 °C
Storage: -40 °C to 60 °C
2 Fluke Corporation
287 True-rms Electronic Logging Multimeter with TrendCapture
Fluke 287
Yes
100 kHz
Yes
1 µV
up to 500 M
50.00 nS
Yes
Battery/fuse
Yes
Yes
Yes
250 µS
0.01 % to 99.99 %
0.025 ms, 0.25 ms, 2.5 ms, 1250.0 ms
Yes
Yes
Yes
Yes
Yes
Yes
up to 10,000 readings
Relative humidity: 0 to 90 %
(0 t 37 °C), 0 to 65 % (37 °C to
45 °C), 0 to 45 % (45 °C to 55 °C)
Electromagnetic compatibility:
EMC EN61326-1
Vibration: Random vibration per
MIL-PRF-28800F Class 2
Shock: 1 meter drop per IEC/EN
61010-1 2nd Edition
Size (HxWxL): 22.2 cm x 10.2
cm x 6 cm (8.75 in x 4.03 in x
2.38 in)
Weight: 870.9 g (28 oz)
Basic Accuracy
0.025 %
0.4 % (true-rms)
0.15 %
0.7 % (true-rms)
1.0 %
0.05 %
1.0 %
0.005 %
Ordering
information
287
True-rms Electronics
Logging Multimeter
with TrendCapture
Optional accessories
FVF-SC2 FlukeView
®
Software with Cable
80BK
Integrated DMM
Temperature Probe
TLK287 Electronic Test Lead Set
TPAK
Magnetic Hanging Kit
C280
Soft Case
Fluke. Keeping your world
up and running.
Fluke Corporation
PO Box 9090, Everett, WA USA 98206
Fluke Europe B.V.
PO Box 1186, 5602 BD
Eindhoven, The Netherlands
For more information call:
In the U.S.A. (800) 443-5853 or
Fax (425) 446-5116
In Europe/M-East/Africa +31 (0) 40 2675 200 or
Fax +31 (0) 40 2675 222
In Canada (800)-36-FLUKE or
Fax (905) 890-6866
From other countries +1 (425) 446-5500 or
Fax +1 (425) 446-5116
Web access: http://www.fluke.com
©2007 Fluke Corporation. All rights reserved.
Specifications subject to change without notice.
Printed in U.S.A. 5/2007 3032814 D-EN-N Rev A