Keep the air hose as short and free of cur-
ves as possible to avoid bottlenecks.
Air-conditioning with installation
If required, your appliance can be installed semi-
permanently (Fig. 6).
Proceed as follows:
• Drill a 5.27 inch (134 mm) dia. hole in an
outside wall or through a window pane, re-
specting the heights shown in fig. 7.
6
12 inch
30 cm
• Fit the flange accessory (S) provided in the
hole following the indications in figs. 8, 9 and
10.
7
8
in the window pane
12 inch
30 cm
• Fit the air exhaust hose (K) in the housing at
• Fit the end of the hose to the flange (S).
• Remove the cap at the back of the appliance
MAX 39 inch
MIN 14 inch
ves as possible to avoid bottlenecks.
permanently, you should leave a door slightly
open, as little as 0.5 inch (1 cm), to guarantee
correct ventilation.
6
9
in the wooden kickboard of a French window
10
in the wall: you are recommended to insulate
the section of wall using suitable insulation.
the back of the appliance (fig. 1).
When the hose is not fitted, the hole can be
closed with the flange cap.
(G) and replace with the drain hose plus cap
(U) as shown in figure 11. This enables the
condensate to be drained more easily at the
end of the season. See the section: "END OF
SEASON OPERATIONS".
Keep the air hose as short and free of cur-
When installing the air conditioner semi-
11