Installation; Mounting Requirements; Bare Board Installation - Zeta ZNDC Installation And Operating Manual

Networked digital communicator
Table of Contents

Advertisement

Zeta Alarm Systems.
3 .
I n s t a l l a t i o n
3 . 1 M o u n t i n g R e q u i r e m e n t s
Zeta Alarm Systems requires that the ZNDC be mounted inside one of our UL listed enclosures,
and be powered from an IPB-3 (Inline Power Booster), Sigma Mk II or Classic 2000 Mk II continu-
ous 24VDC output. The ZNDC should be mounted using the supplied components. The four plas-
tic standoffs snap into the ZNDC board, and the four screws are used to secure the standoffs to a
flat surface. The ZNDC board requires four mounting holes (0.3125" diameter) placed in a rectan-
gle, with 5.30" horizontal spacing, and 2.95" vertical spacing.
3 . 1 . 1 B a r e B o a r d I n s t a l l a t i o n
All mounting accessories are included in Installation Kit.
If you wish to mount the ZNDC inside the panel cabinet, Zeta Alarm Systems requires that you
place the panel batteries in a companion battery cabinet next to the panel cabinet, freeing the
back wall of the cabinet to mount the ZNDC. Use the template in Appendix A of this manual to
accurately drill the holes for the board.
After drilling the holes, attach the stand-offs to the cabinet. Position the board over the stand-
offs so that the four holes in the board match up with the standoffs. Snap board onto standoffs.
Revision 1.0
ZNDC Installation and Operation Manual
Figure No. 3.0A
Part # MAN-ZNDC-01
Page 6