Connecting The Range To Gas - GE EGR3000 Owner's Manual & Installation Instructions

Self-cleaning gas ranges
Table of Contents

Advertisement

Installation instructions
[]
PROVIDE ADEQUATE
GAS SUPPLY
Your
range
is designed
to operate
at a pressure
of 4" of
water
column
on natural
gas or, if designed
for LP gas
(propane
or butane),
10" of water
column.
Make
sure
_tl
are suppl)_ng
your
range
with
tile type
of
gas ib_ which
it is designed.
This
range
is convertible
%r
use on natural
or propane
gas. If you
dedde
to use this range
on LP gas, c(mvel_ion
I/ltlSt be made
by a qualified
I2
installer
before
attempting
to operate
tile range
on that
gas.
For proper
operation,
tile pressure
oI natural
gas
supplied
to tile tegulator
nmst
be between
4" and
13"
of water
cohlI//n.
For I,P gas, tile pressure
supplied
nmst be between
10"
and 13" of water cohmm.
When
checking
flw proper
operation
of tile regulatoi;
tile inlet pressure
nmst be at least 1" greater
than tile
operating
(inanifl)ld)
pressure
as given above.
Tile pressme
regulator
located
at tile inlet of tile range
manilbld
must remain
ill the supply line regardless
ot
whether
natural
or I,P gas is being used.
A fle_ble
metal appliance
connector
used to connect
tile
range to tile gas supply line shouM
have an I.D. ot 1/2"
and be 5 teet in length
fi)r ease ot installation.
In Canada,
fle_ble
connecto[3
Ill{IS[ be single wall metal coimectoi3
no longer
than 6 feet in length.
[]
CONNECT THE RANGE TO GAS
Shut off the main gas supply valve before
disconnecting
the old range and leave it off until the new hookup
has
been completed.
Don't forget
to relight the pilot on other
gas appliances
when you turn the gas back on.
Because
hard piping
restricts
n/ovement
of tile range,
tile use (ff a CSA International-certified
flexible
metal
appliance
connector
is recommended
unless local codes
require
a hard-piped
connection.
Never use all oM connector
when
installing
a new range.
If tile hard piping
method
is used, you I/lust carefl/lly
align tile pipe; the range
cannot
be mored
alter tile
c(}nnection
is
made.
To pre', ent gas leaks, put pipe joint compound
oil, or
wrap pipe thread
rope with Teflon*
around,
all male
(external)
pipe threads.
A. lnsmll a manual
gas line shut-off
_;dve ill the gas lille ill
an easily accessed
location
(/utside of the range.
Make
sure everyone
operating
tile range kno_vs where and
how to shut off the gas supply to tile range.
B. Install male 1/2" flare union
adapter
to tile 1/2" NPT
internal
thread
at inlet of regulatol:
Llse a backup
wrench
on tile regulator
fitting
to avoid damage.
When
installing
the iange
ti'oln the ti'ont, relnove
the
90 ° elbow for easier installation.
C. Install inale
1/2" or 3/4" flare union
adapter
to tile
NPT internal
thread
of the inanual
shut-off \:five,
taking care to back-up
tile shut-off ',_flve to kee I) it
fl'oln mrning.
D. Connect
flexible
inetal appliance
connector
to the
adapter
on tile range.
Position
range to pemfit
connection
at tile shin-off wflve.
E.
X_]/en all connections
have been inade,
inake sure
all range
controls
are in the off position
and turn on
the main gas supply \;five. Use a liquid leak detector
at all joints
and connections
to check tor leaks in
the system,
When
using
test pressures
greater
than
1/2 psig to
pressure
test the gas supply
s):steln of the residence,
disconnect
tile range
and individual
shut-off
valve
WARNING:
oo
NOT
USE A FLAME
TO
CHECK
FOR
GAS LEAKS.
fl'Oln tile gas supply
piping.
When
using test pressures
of 1/2
psig or less to test tile gas supply
systeln,
silnply
isolate
the range
ti'om
the gas supply
system
by closing
the individual
shut-off
valve.