Campbell CS205 Instruction Manual

10-hour fuel temperature stick
Hide thumbs Also See for CS205:

Advertisement

Quick Links

Model CS205 10-Hour
Fuel Temperature Stick
Revision: 5/08
C o p y r i g h t
©
1 9 9 8 - 2 0 0 8
C a m p b e l l
S c i e n t i f i c ,
I n c .

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the CS205 and is the answer not in the manual?

Questions and answers

Summary of Contents for Campbell CS205

  • Page 1 Model CS205 10-Hour Fuel Temperature Stick Revision: 5/08 C o p y r i g h t © 1 9 9 8 - 2 0 0 8 C a m p b e l l S c i e n t i f i c ,...
  • Page 2 Warranty and Assistance The MODEL CS205 10-HOUR FUEL TEMPERATURE STICK is warranted by CAMPBELL SCIENTIFIC, INC. to be free from defects in materials and workmanship under normal use and service for twelve (12) months from date of shipment unless specified otherwise. Batteries have no warranty.
  • Page 3 5.2 CR10X Programming ................4 6. Maintenance and Calibration........4 Figures 3-1. Exploded View of CS505 and CS205 Mounting ........1 3-2. CS205 Mounts on the Mounting Stake with the CS505......2 6-1. 107 Thermistor Probe Schematic ............4 Tables 4-1. Wiring for CS205 ..................2...
  • Page 5: General Description

    Stick 1. General Description The CS205 Temperature Stick is a Ponderosa pine dowel 4.5 inches long and 0.5 inches in diameter. The dowel is fabricated to USFS specifications, to be used as a fuel moisture sensor. Campbell Scientific, Inc. has bored a hole and cut a split into one end of the dowel.
  • Page 6 Model CS205 10-hour Fuel Temperature Stick FIGURE 3-2. CS205 Mounts on the Mounting Stake with the CS505 4. Wiring Connections to Campbell Scientific dataloggers are given in Table 4-1. Temperature is measured with one Single-Ended input channel and an Excitation channel.
  • Page 7: Datalogger Programming

    5. Datalogger Programming This section is for users who write their own datalogger programs. A datalogger program to measure this sensor can be created using Campbell Scientific’s Short Cut Program Builder software. You do not need to read this section to use Short Cut.
  • Page 8: Maintenance And Calibration

    The 107 Probe requires minimal maintenance. Please refer to the 107 manual for more detail. The CS205 Fuel Moisture Stick should be changed annually or more frequently as required. The wood should visually appear fresh and new not gray or discolored.
  • Page 9 This is a blank page.
  • Page 10 Campbell Scientific Companies Campbell Scientific, Inc. (CSI) 815 West 1800 North Logan, Utah 84321 UNITED STATES www.campbellsci.com info@campbellsci.com Campbell Scientific Africa Pty. Ltd. (CSAf) PO Box 2450 Somerset West 7129 SOUTH AFRICA www.csafrica.co.za cleroux@csafrica.co.za Campbell Scientific Australia Pty. Ltd. (CSA)

Table of Contents