HKV 300 Blower Performance
All Data is Wet Coil
10600
BHP
3.68
10600
Sheave/Mtr
B
10600
RPM
680
10600
Turns Open
4.5
10800
BHP
3.88
10800
Sheave/Mtr
B
10800
RPM
691
10800
Turns Open
4.5
11000
BHP
4.08
11000
Sheave/Mtr
B
11000
RPM
704
11000
Turns Open
3.5
11200
BHP
4.28
11200
Sheave/Mtr
B
11200
RPM
714
11200
Turns Open
3.5
11400
BHP
4.48
11400
Sheave/Mtr
B
11400
RPM
726
11400
Turns Open
3
11600
BHP
4.68
11600
Sheave/Mtr
B
11600
RPM
738
11600
Turns Open
2.5
11800
BHP
4.88
11800
Sheave/Mtr
B
11800
RPM
750
11800
Turns Open
2
12000
BHP
5.08
12000
Sheave/Mtr
D
12000
RPM
758
12000
Turns Open
6
12200
BHP
5.28
12200
Sheave/Mtr
D
12200
RPM
769
12200
Turns Open
6
12400
BHP
5.68
12400
Sheave/Mtr
D
12400
RPM
781
12400
Turns Open
5.5
12600
BHP
5.88
12600
Sheave/Mtr
D
12600
RPM
793
12600
Turns Open
5
A = Standard Static/Standard Motor, B = Low Static/Standard Motor, C = High Static/Standard Motor, D = Standard Static/Large Motor, E = High Static/Large Motor
Unit factory shipped with standard static sheave and drive at 2.5 turns open. Other speed require field selection.
For applications requiring higher static pressures, contact your local representative. Performance data does not include drive losses and is based on sea level conditions.
Do not operate in black regions. All airflow in rated at lowest Voltage if unit is dual Voltage rated, i.e. 208V for 208-230V units.
For dry coil performance first calculate the face velocity of the air coil (Face Velocity [FPM] = Airflow [CFM] / Face Area [sqft]). Then use preceding wet coil to dry coil conversion table.
HKV LArge CommerCiAL
Table Continued from Previous Page
3.88
4.08
4.28
4.48
B
B
B
A
709
737
763
790
3.5
3
2
5.5
4.08
4.28
4.48
4.68
B
B
A
A
717
745
772
799
3.5
2.5
6
5
4.28
4.48
4.68
4.88
B
B
A
A
729
756
783
810
3
2
5.5
5
4.48
4.68
4.88
5.08
B
A
A
D
740
767
794
818
2.5
6
5.5
4.5
4.68
4.88
5.08
5.28
B
A
D
D
752
779
803
829
2
5.5
5
4.5
4.88
5.08
5.28
5.48
A
D
D
D
763
788
813
839
6
5.5
4.5
4
5.08
5.28
5.48
5.78
D
D
D
D
775
799
824
849
5.5
5
4
3.5
5.28
5.48
5.78
6.08
D
D
D
D
783
808
833
858
5.5
4.5
4
3.5
5.48
5.78
6.08
6.28
D
D
D
D
794
819
843
866
5
4.5
4
3
5.88
6.08
6.28
6.48
D
D
D
D
815
830
854
878
4.5
4.5
3.5
3
6.08
6.28
6.58
6.88
D
D
D
D
817
841
863
886
4.5
4
3
2.5
4.68
4.88
5.08
5.28
A
A
D
D
817
842
867
889
4.5
4
3
2.5
4.88
5.08
5.28
5.48
A
D
D
D
825
850
873
897
4.5
3.5
3
2
5.08
5.28
5.48
5.68
D
D
D
D
836
859
883
907
4
3
2.5
2
5.28
5.48
5.68
6.00
D
D
D
D
844
868
892
916
3.5
3
2.5
1.5
5.48
5.78
6.08
6.28
D
D
D
D
854
878
902
925
3.5
3
2
1.5
5.68
6.00
6.28
6.48
D
D
D
D
864
888
911
934
3
2.5
2
1
6.08
6.28
6.48
6.68
D
D
D
D
874
898
921
944
3
2.5
2
1
6.28
6.48
6.68
6.98
D
D
D
E
880
904
927
950
2.5
2
1.5
3.5
6.48
6.68
6.98
7.28
D
D
D
E
890
913
936
958
2.5
2
1.5
3
6.78
7.08
7.28
7.48
D
D
D
E
900
923
946
968
2
1.5
1
3
7.08
7.28
D
D
910
933
2
1.5
34
IOM Instructions
Blower Performance
5.48
5.68
5.88
6.18
D
D
E
E
912
935
957
979
2
1
3
2.5
5.68
5.88
6.18
6.38
D
E
E
E
920
943
965
986
1.5
3.5
3
2.5
6.18
6.28
6.48
6.68
D
E
E
E
929
952
972
993
1.5
3.5
3
2.5
6.28
6.48
6.68
6.88
D
E
E
E
938
959
981
1002
1
3
2.5
2
6.48
6.68
6.88
7.18
D
E
E
E
948
970
990
1011
1
3
2.5
2
6.68
6.88
7.18
7.48
E
E
E
E
955
977
998
1019
3.5
2.5
2
1.5
6.98
7.28
7.48
E
E
E
964
986
1007
3
2.5
2
7.28
7.48
E
E
972
993
3
2.5
7.48
E
980
2.5
6.38
6.58
6.78
E
E
E
1000
1021
1042
2
1.5
1
6.58
6.78
6.98
E
E
E
1006
1026
1047
2
1.5
1
6.88
7.08
7.38
E
E
E
1014
1035
1055
2
1
0.5
7.08
7.38
E
E
1023
1043
1.5
1
7.48
E
1031