AR3030 operating manual

7-5 Monitoring the contents of received serial data

CMD
Data to be transmitted
D [CR]
All received data. Go to VFO mode
from Memory mode.
Y [CR]
Send signal level (64 div 00 - 3F)
nn M [CR]
Go to Memory mode after sending
data of selected memory channel.
- nn = 00 ~ 99
Data of the selected memory channel
- nn = BLANK
Data of the present memory channel

7-6 FORMAT 1 - Contents of the received signal

Contents of serial data ==> D Rn Gn Bn Tn Fnnnnnnnn C [CR] [LF]
Contents of each TX
Details
D
- HEADER D(DIAL)
Rn
- ATT position
Gn
- AGC position
Bn
- Filter position
Tn
- Tone position
Fnnnnnnnn
- Receive Frequency Present frequency
- Other than VHF band 0nnnnnnn
- VHF band
C or
- Present mode
U or
L or
A or
42
FORMAT
1
2
3
n = 0
OFF
n = 1
10dB
n = 2
20dB
n = 0
Slow
n = 1
Fast
n = 0
Normal
n = 1
Narrow
n = 0
Low
n = 1
High
(LSD = 10Hz)
nnnnnn00
C
C W
U
USB
L
LSB
A
A M