MODENA S HE
Position of terminals
A
Directly under an opening, air inlet, openable window, etc.
B
Above an opening, air inlet, openable window, etc.
C
Horizontally to an opening, air inlet, openable window, etc.
D
Under gutters, drain pipes
E
Under cornices or under eaves
F
Under balconies or garages
G
From a drain pipe or a vertical drain pipe
H
From an internal or external corner
I
Above ground level, a roof or balcony
J
From a surface facing the terminal
K
From a terminal facing the terminal
L
From a garage opening (e.g. door, window) with access to the home
M
Vertically from a terminal on the same wall
N
Horizontally from a terminal on the same wall
O
From the wall on which the terminal is fitted
P
From a vertical structure on the roof
Q
Above the intersection with the roof
•
N/A = Not applicable
•
Also, the terminal must be at least 150 mm (in case of forced intake) from an opening made in the structure of
the building to house a fitted element such as a window frame.
•
Positions of condensate drain terminals: if the fume exhaust is provided for at a low level, the potential effect of
NOTES
the flue gas cloud must be considered. Special flue gas management kits are available by request.
•
The flue gas cloud must not be directed towards:
-
A frequented approach
-
A window or door
-
An adjacent property
EN
fig. 22
Minimum dimensions of fume exhaust terminals
cod. 3541C364 - Rev. 00 - 12/2012
300 mm
300 mm
300 mm
75 mm
200 mm
200 mm
150 mm
100 mm
300 mm
600 mm
1200 mm
1200 mm
1500 mm
300 mm
N/A
150 mm
300 mm
17