Trouble Shooting - Daikin FVXS60HVMA Operation Manual

Room air conditioner
Hide thumbs Also See for FVXS60HVMA:
Table of Contents

Advertisement

Trouble Shooting

These cases are not troubles.
The following cases are not air conditioner troubles but have some reasons. You may just continue using it.
Case
Operation does not start soon.
When ON/OFF button was pressed soon
after operation was stopped.
When the mode was reselected.
Hot air does not fl ow out soon after
the start of heating operation.
The heating operation stops suddenly
and a fl owing sound is heard.
The outdoor unit emits water or
steam.
Mist comes out of the indoor unit.
The indoor unit gives out odour.
The outdoor fan rotates while the air
conditioner is not in operation.
The operation stopped suddenly.
(OPERATION lamp is on.)
No remote controller signals are
displayed.
The remote controller sensitivity is
low.
The display is low in contrast or
blacked out.
The display runs out of control.
The ON/OFF TIMER does not operate
according to the settings.
30
This is to protect the air conditioner.
You should wait for about 3 minutes.
The air conditioner is warming up. You should wait for 1 to 4 minutes.
(The system is designed to start discharging air only after it has reached a certain
temperature.)
The system is taking away the frost on the outdoor unit.
You should wait for about 4 to 12 minutes.
In HEAT mode
The frost on the outdoor unit melts into water or steam when the air conditioner is in
defrost operation.
In COOL or DRY mode
Moisture in the air condenses into water on the cool surface of outdoor unit piping and
drips.
This happens when the air in the room is cooled into mist by the cold airfl ow
during cooling operation.
This is because the air in the room is cooled by the heat exchanger and
becomes mist during defrost operation.
This happens when smells of the room, furniture, or cigarettes are absorbed
into the unit and discharged with the airfl ow.
(If this happens, we recommend you to have the indoor unit washed by a
technician. Consult the service shop where you bought the air conditioner.)
After operation is stopped:
The outdoor fan continues rotating for another 60 seconds for system protection.
While the air conditioner is not in operation:
When the outdoor temperature is very high, the outdoor fan starts rotating for system
protection.
For system protection, the air conditioner may stop operating on a sudden large voltage
fl uctuation.
It automatically resumes operation in about 3 minutes.
The batteries are dying and the remote controller is malfunctioning. Replace all the
batteries with new size batteries, AAA.LR03 (alkaline). For details, refer to "To set the
batteries" of this manual.
Page 8
Check if the ON/OFF TIMER and the WEEKLY TIMER are set to the same time.
Change or disable the settings in the WEEKLY TIMER.
Explanation
Page 20

Hide quick links: