TROUBLE SHOOTING

Trouble Shooting
These cases are not troubles.
The following cases are not air conditioner troubles but have some reasons. You may just continue using it.
Case
Does not operate at all.
Operation does not start soon.
• When ON/OFF button was pressed
soon after operation was stopped.
• When the mode was reselected.
Hot air does not flow out soon after
the power supply is turned on.
The heating operation stops suddenly
and a flowing sound is heard.
A "Zeen" sound is heard immediately
after the power supply is turned on.
A continuous low "Shah" sound is
heard when the system is in cooling
operation or at a stop.
A "Pishi-pishi" squeaking sound is
heard when the system stops after
heating operation.
A low "Sah", "Choro-choro" sound is
heard while an indoor unit has stopped.
A continuous low "Shuh" sound is
heard when the systems is in cooling
or defrost operation.
A "Shuh" sound which is heard at the start
or immediately after the stop of operation
or which is heard at the start or immediately
after the stop of defrost operation.
When the tone of operating noise changes. • This noise caused by the change of frequency.
A continuous "shuh" sound generated
during operation or immediately after
the operation is started or stopped.
The outdoor unit emits water or steam. „ In heating mode
Mists come out of the indoor unit.
• Check if the fuse has blown.
Set power switch to off.
• Check if breaker has worked.
Turn the power on with the breaker switch in the
off position.
Do not turn the power on with the breaker switch in the trip position.
(Contact your dealer.)
• When the power is interrupted.
Wait until the power is recovered, then operate the air conditioner again.
The air conditioner automatically resumes operation in about 3 minutes.
You should just wait for a while.
• This is to protect the air conditioner.
You should wait for about 5 minutes.
(The microcomputer is preparing for operation. Wait for about 10 minutes.)
• The air conditioner is warming up. You should wait for about 1 minute. (The system
is designed to start discharging air only after it has reached a certain temperature.)
• The system is taking away the frost on the outdoor unit.
You should wait for about 3 to 8 minutes. (Max. 10 minutes).
• This sound indicates that the valve for the refrigerant bypass is in operation.
• The electronic expansion* valve inside an indoor unit starts working and
makes the noise. Its volume will reduce in about one minute.
* Electronic expansion valve ... Controls the flow rate of the gas
(refrigerant) flowing inside the indoor unit.
• When the drain pump (optional accessories) is in operation, this noise is
heard.
• Expansion and contraction of plastic parts caused by temperature change
makes this noise.
• When the other indoor unit is in operation, this noise is heard. In order to prevent oil and
refrigerant from remaining in the system, a small amount of refrigerant is kept flowing.
• This is the sound of refrigerant gas flowing through both indoor and
outdoor units.
• This is the noise of refrigerant caused by flow stop and flow change.
• This sound indicates that the valve for the refrigerant bypass is in operation.
• The frost on the outdoor unit melts into water or steam when the air
conditioner is in defrost operation.
„ In cooling or dry mode
• Moisture in the air condenses into water on the cool surface of outdoor
unit piping and drips.
• This happens when the air in the room is cooled into mist by the cold
airflow during cooling operation.
• If the inside of an indoor unit is extremely contaminated, the temperature
distribution inside a room becomes uneven. It is necessary to clean the
inside of the indoor unit. Ask your Daikin dealer for details on cleaning the
indoor unit. This operation requires a qualified service person.
TROUBLE SHOOTING
Explanation
Breaker
ON
Switch
Trip position
OFF
14

Advertisement

Table of Contents