Hold coupling nut and regulator
as shown for proper connection
to LPtank valve.
Leak Testing Valves,
Hose and Regulator
1.Turnall grill control knobsto OFF.
2Be sure regulator
is tightly connected
to LPtank
3Completely
open LP tank valve by turning OPD hand wheel
counterclockwise
If you hear a rushing sound, turn gas off
immediately There is a major leak at the connection Correct
before proceeding by calling Sears for replacement parts at
1-800-4-MY-HOME ®
4Brush soapy solution onto areas where bubbles are shown in
picture below:
6 Turn the coupling nut clockwise and tighten to a full stop The
regulator will seal on the back-check feature in the LPtank
valve, resulting in some resistance An additional one-half to
three-quarters turn is required to complete the connection.
Tighten by hand only - do not use tools.
NOTE:
If you cannot complete the connection, disconnect regulator
and repeat steps 5 and 6. If you are still unable to complete the
connection, do not use this regulator!
Call 1-800-4-MY-HOME ® for an identical replacement part.
Never remove threaded
orifice at:nd
of valve.
• Do not insert any tool or foreign object into the valve
outlet or safety relief valve You may damage the valve
and cause a leak Leaking propane may result in
explosion, fire, severe personal injury, or death
• Outdoor gas appliance is not intended to be installed
in or on a boat
• Outdoor gas appliance is not intended to be installed
in or on an RV
• Never attempt to attach this grill to the self-contained
LPgas systemof a camper trailer or motor home
• Do not usegrill until leak-tested
• If a leak is detected at any time, STOPand call the fire
department
• If you cannot stop a gas leak, immediately close
LPcylinder valve and call LPgas supplier or your fire
department !
5 If _'growing_'bubbles appear, there is a leak Close LPtank
valve immediately and retighten connections If leaks cannot be
stopped do not try to repair Call for replacement
parts at 1-800-4-MY-HOME®
6 Always close LPtank valve after performing leak test by
turning hand wheel clockwise