Step 20. At arm's length away,set the thermostat to desired set-
ting. The mark (V) HOT indicative of approx. 120°F is
preferred starting point. If hotter water is desired see the
"Temperature Regulation" section in this manual.
"A"(
KNOB
_WARNING.
I
Hotter
water
increases
the rtsk of scald injury. I
Before
changing
temperature
setting
see the
"Temperature
Regu ation" section n th s manua.
GAS
LINE
Step 21. Replace the outer door if not replaced in step 17.
Step 22. Remove adhesive label found in conversion kit and
place next to the model rating plate. Mark label indi-
cating for which type gas the water heater is now
equipped.
z
"Fuel"
Conversion
Instructions
From Propane
(L.P.) Gas To Natural
Gas
AWARNING
This water heater has been factory equipped to operate
with the type gas indicated in the "EQUIPPED FOR" area
of the model rating plate located near the gas control
valve. The indicated gas may be either Natural or
Propane (L.R). By following the conversioninstructionsin
this manual or the instructionsnear the gascontrol valve,
the water heater must be converted if it is to be used
with the opposite gas. DO NOT USE THIS WATER
HEATER WITH
ANY GAS OTHER THAN THE ONE
LISTED ON THE MODEL RATING PLATE. Failure to use
the correct gas can cause problems which can result in
DEATH, SERIOUS BODILY INJURY, OR PROPERTY
DAMAGE. If you have any questions or doubts consult
your gassupplier or gascompany.
To convert
from Propane
(L.E) gas to Natural
gas, follow the
"Fuel"
Conversion
Instructions
From
the "Natural
Gas to
Propane
(LP.) Gas" section except in Step 5, use orifice 'E",
marked "NAT.". In Step 6 use pilot orifice "G',
brass color and
in Step 8 turn control screw "B" in Figure 1 clockwise (f'-_',)
to stop. Screw must be in "OUT"
position for Natural gas.
See "Instruction
Label" for orifice sizes.
Maximum Supply Pressure:
14"W.C. For Nat. Gas.
14" W.C. for Propane (L.P.) Gas
Minimum Supply Pressure
5"W.C. for Nat. Gas.
11" W.C. For Propane (L.P.) Gas
TEMPERATURE
/-- PLASTIC CAP
ADJ. DIAL
--
/
[ Figure I ]
OUTFOR NATURAL
IN FOR PROPANE (L.E)
THERi_qOCOUPLE J_
LJ.
J-_ PILOT TUBING
[ Figure 21
MANIFOLD
BURNER
F,2 i
[_
"F"
17

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

153.333931The economizer 5

Table of Contents