Filling The Water Heater; Venting - Kenmore The economizer 5 Gas water heater 153.333831 Owner's Manual

The economizer 5 mobile home gas water heater
Hide thumbs Also See for The economizer 5 Gas water heater 153.333831:
Table of Contents

Advertisement

Installation
Instructions (cont'd)
Filling the Water
Heater
CAUTION
Never usethis water heater unless it iscompletelyfilled
water. To prevontdamageto the tank, the tank must befilled _
with water.. Water must flow from the hot water faucet
beforetummg ON gasto the water heater.
To fill the water heater with water:
Close the water heater drain valve by turning
the handle
to
the right (clockwise). The drain valve is on the lower front of
the water heater.
Open the cold water supply valve to the water heater.
NOTE:
The cold water supply
valve must be left open
when the water heater is in use.
To insure
complete'
filling of the tank, allow air to exit by
opening
"the nearest
hot water faucet.
Allow water to run
until a constant
flow is obtained. This will let air out of the
water heater and the piping.
Check all new water piping for leaks. Repair as needed.
Venting
Place the draft hood legs in the receiving holes on the top of
the water heater. The legs will snap in the holes to give a
tight fit.
Place the vent pipe over the draft hood. With the vent pipe
in position, drill a small hole through both the vent pipe and
draft hood. Secure them together with a sheet metal screw.
DRAFT
HOOD
INSTALLATION
DRAFT HOOD
!
VENT
TO
OUT-
DRAFT
DOORS OR
HOOD
CHIMNEY
_SCREW_ l_
I
DRAFT
_E,WARNING
VENT DAMPERS - Any vent damper, whether it is
operated thermally or otherwise must be removed if its
use inhibits proper drafting of the water heater.
Thermally Operated
Vent Dampers: Gas-fired water
heaters having thermal etficiency in excess of 80% may
_roduce a relatively low flue gas temperature.
Such
temperatures may not be high enough to properly open
thermally operated vent dampers. This would cause
spillage of flue gases and may cause carbon monoxide
poisoning.
Vent dampers must bear evidence of certification as
complying with the latest edition of the American
National Standard ANSI Z21.68 (ANSI Z21.66 & 67,
respectively, cover electrically and mechanically actuat-
ed vent dampers). Before installation
of any vent
damper, consult the local Sears Service Center or gas
utility for further information.
AWARNING
To insure proper venting of this gas-fired water heater, the
correct vent pipe diameter must be utilized. Any additions or
deletions of other gas appliances on a common vent with this
water heater may adversely affect the operation of the water
heater. Consult the local Sears Service Center or gas utility if
any such changes aro planned.
Check the venting system for signs of obstruction or deterioration
and replace if needed.
The combustion
and ventilation air flow must not be obstructed.
AWARNING
1
The water heater with draft hood inst_led must be properly
vented to a chimney which terminates outdoors. Never oper-
ate the water heater unlessit is vented to the outdoors and has /
adequate air supplyto avoid risksof improper operation, explo-
sion
or asphyxiation.
]
AWARNING
Obstructed or deteriorated ventsystems maypresenta serious
healthrisk or asphyxiation.
All vent gases must be completely vented to the outdoors
of the
structure
(dwelling).
Installonly
the draft hood provided
with
the new water heater and no other draft hood.
Vent pipes must be secured at each joint with sheet metal screws.
The water heater
must be connected
to a roof jack: The vent
pipe from the water heater to the roof jack must, be no less than
the diameter
of the draft hood outlet
(min. 3 ) on the water
heater.
This water heater may be installed with single wall or Type B
vent pipe connection
to the draft hood and the following U.L.
listed ruofjacks
not furnished.
Triangle Products No. 773-50
Vent Line No. 2073
Strawsine No. 73T
White Metal Products 3RJ
There must be a minimum
clearance of 12" between the top of
the draft hood and the top of the enclosure.
The draft hood and combustion
air inlet to the water heater
must be in the same atmospheric pressure zone. Do not separate
by a wall, shelf, ceiling, partition,
or any other means.
AWARNING
I
Failure to have required clearances between vent
piping and combustible material will result in a fire
hazard.
AWARNING
I
Be sure vent pipe is properly connected to prevent I
escapeof dangerousflue gaseswhich could causedeadly
asphyxiation.
14