Setting Format of [config.txt] File
Item
Printer Language
Host Name
Workgroup
NETBEUI
TCP/IP
Spool
Max Spool Size
Max Receive Buffer Size
Auto Driver Download
JCL
Print Mode
Auto Master Mode
Encrypt Password
Time Zone
Daylight Savings
Maximum Session
Unicode Support
DHCP
Get WINS DHCP
IP Address
Subnet Mask
Gateway Address
WINS Primary Server IP
Address
WINS Secondary Server
IP Address
Administrator Name
Administrator Password
Remarks
Language to be used.
Host name of the printer.
Name of workgroup of printer.
Activation of NetBEUI protocol.
Activation of TCP/IP protocol.
Activation of spool function.
Can select from Disk, Memory, and Off.
If Disk is not recognised when it is selected,
it will become Memory.
The maximum receive buffer size during
spooling.
Can be set in 256 kbyte units.
The maximum receive buffer size during
non-spooling.
Can be set in 32 kbyte units.
Activation of the automatic downloading of
printer driver.
Activation of JCL.
Set the printer language.
Activation of the automatic browse master
feature.
Not available when Wins server is
designated.
Activation of the encrypt password feature.
Set the time zone in units of minutes.
Set the period of summer time.
Maximum connections of printer.
Set whether to use unicode or local code
(Shift JIS).
Activation of the DHCP protocol.
Set whether or not to get WINS from the
DHCP server.
Set the IP address.
Set the subnet mask.
Set the gateway address.
Set the WINS primary server IP address.
Set the WINS secondary server IP address.
Name Administrator name.
Password of administrator.
Current setting not displayed.
Value
English
Maximum 15 bytes
Maximum 15 bytes
On/Off
On/Off
Disk/Memory/ Off
512 - 32768 (unit:
kbyte)
64 - 1024 (unit:
kbyte)
Enabled/Disabled
On/Off
AUTO/PS/HPGL/
PCL/ESCP/TIFF
On/Off
On/Off
-720 to 720 (unit:
minutes)
hour-start-end (h-
hhddmm-
hhddmm)
3 - 10
Enabled/Disabled
On/Off
Yes/No
-----
-----
-----
-----
-----
Maximum 20 bytes
Maximum 14 bytes
4.2 Setting/Changing SMB Using the [Config.txt] File
Factory default
English
OKI-xxxxxx (xxxxxx: last 6
characters of the printer
MAC address)
WORKGROUP
Off
On
Off
1024 kbyte
256 kbyte
Enabled
On
AUTO
On
On
0 (England)
5
Disabled
Off
No
0.0.0.0
0.0.0.0
0.0.0.0
0.0.0.0
0.0.0.0
ADMIN
xxxxxx (the last six
characters of the printer's
MAC address)