3.7

Selecting the Training Speed

The training speed selects how fast the transducer scans the display sector. Two choices are
available, 3 (normal speed, default setting) and 6 (high speed), and one may be selected with
the [FAST SCAN] key. Each time the key is pressed the display momentarily shows "NORM"
(normal speed) or "FAST" (high speed).
Normal: 60 transmissions for half circle in increments of 3 .
High:
30 transmissions for half circle in increments of 6 .
3.8

Finding Echo Position with the Cursor

The cursor measures horizontal range and depth. Operate the Omnipad to place the cursor
where desired. Cursor data appears at the top left-hand corner on the screen.
: Horizontal range
: Depth
Figure 3-10 Location of cursor position data
Cursor data