INLET- OUTLETPLUMBINGOPTIONS
Install a single bypass valve (provided)
to the plumbing,
as shown in Fig. 8 OR if desired,
a 3 valve bypass sys-
tem (parts not included)
can be installed,
as shown in
Figure 7. Bypass valves allow you to turn off water to
the Central
Water
Whole
Home Filtration
System for
maintenance
if needed,
but still supply water
to the
house.
Use either:
• Copper
pipe
• Threaded
pipe
PEX (Crosslinked
Polyethylene)
pipe
• CPVC plastic
pipe
• Other
pipe approved
for use with potable
water
IMPORTANT:
Do not solder with plumbing
attached
to
installation
adapters
and single valve
bypass.
Soldering
heat will damage
the
adapters
and valve.
NOTE: Before installing
the bypass valve or copper
tube into the valve's INLET, remove the foam
piece that was placed
in that port for shipping.
Before installing
the bypass valve or copper
tube into
the valve's OUTLET, make sure that the turbine
and sup-
port are firmly
in place, as shown in Figure 6.
Turbine
Valve
.Support
Outlet
Turbine
/
Figure 6
3 VALVE BYPASS
Central
Water
Filtration
SystemOUTLET
Central
Water
Filtration
System INLET
Figure 7
CONNECTING
PLUMBING
TO VALVE
OUT
Use Teflon@ tape,
pipe joint com-
pound
or both
IN
1" NPT Sweat
Adapter
(2)
_._
(not included)
8__
1" NPT
_
Adapter (2)l
Clip (4))
\
Valve
Bypass
Inlet
Valve
Included
Use Teflon@ tape,
pipe joint com-
pound
or both
Valve
Inlet
OUT
IN
1" NPT Sweat
Adapter (2)
(not included)
1" NPT Clip (r_
Adapter
(2)_
Included
Figure 8