Download Print this page

DeVilbiss FA125-1 Owner's Manual

Permanently lubricated air compressor
Hide thumbs Also See for FA125-1:

Advertisement

Quick Links

OWNERS
MANUAL
FOR
PERMANENTLY LUBRICATED AIR COMPRESSOR
(For Home Use Only)
MODEL NO.
FA125-1
SPECIFICATION
CHART
Model
No.
FA125-1
Horsepower
1
SCFM @ 40 psig
3.7
SCFM @ 90 psig
2.7
Cut-In
100 PSI
Cut-Out
125 PSI
Bore
1 3/4"
Stroke
1 1/4"
Voltage-Single
Phase
110-120
Minimum Branch Circuit
Requirement
15 AMPS
*Fuse Type
Quick Acting
Amperage
at Max. Pressure
10
Tank Size
2.5
Gallon
*A circuit breaker
is preferred.
Use only a fuse or circuit breaker that is the
same rating as the branch
circuit the air compressor
is operated
on, If the
air compressor
is connected
to a circuit protected
by fuses, use quick acting
fuses.
NOTE:
For identification
of Repair
Parts, see Page 12 in this
Manual.
IMPORTANT:
Read and retain the Safety
Guidelines
and All Inskuc-
Uons Carefully
Before
Operating.
WARRANTY"
See Page 3 of this Manual
for Warranty
Information.
DeViJbiss
Air Power
Company
. 213
#ndus_ial
Drive
- Jackson,
TN 38307-96?5
I
MGP-FA125-1
11/15/93
I

Advertisement

loading

Summary of Contents for DeVilbiss FA125-1

  • Page 1 OWNERS MANUAL PERMANENTLY LUBRICATED AIR COMPRESSOR (For Home Use Only) MODEL NO. FA125-1 SPECIFICATION CHART Model FA125-1 Horsepower SCFM @ 40 psig SCFM @ 90 psig Cut-In 100 PSI Cut-Out 125 PSI Bore 1 3/4" Stroke 1 1/4" Voltage-Single Phase...
  • Page 2 TABLE OF CONTENTS Page Page ON-RECEIPT INSPECTION ....Location of Air Compressor .... Extension Cords ........ WARRANTY (SP-100-C) ....... Voltage and Circuit Protection ..7 Grounding Instructions ...... SAFETY GUIDELINES ......Additional Regulators Controls ..........WARNING CHART ......Break-In Procedures ......
  • Page 3 Use reasonable care in the operation and maintenance of the product as described in the Owners Manual(s). Deliverorshiptheproduct to the nearest DeVilbiss Air Power Authorized Warranty ServiceCenter. Freight costs, if any, must be paid bythe purchaser. Air compressorswith 60 and 80 gallon tanks only will be inspected at the site of installation. Contact the nearest Authorized Warranty ServiceCenter, that provides on-site servicecalls, for servicecall arrangement.
  • Page 4 SAFETY GUIDELINES "Fhis manual contains information that is important for you to know and understand. This information relates to protecting YOUR SAFETY and PREVENTING EQUIPMENT PROBLEMS. To help you recognize this information, we use the following symbols. Please read the manual and pay attention to these sections. URGENT SAFETY INFORMATION...
  • Page 5 HOW TO PREVENT IT WHAT TO WHAT COULD HAPPEN LOOK FOR Compressed [ Compressed air can propel dust, did or loose Never point any nozzle or sprayer toward a padicles it comes in contact with. These pro- 3erson or any part of the body. pelled particles may cause serious injury or damage.
  • Page 6 DUTY CYCLE All DeVilbiss Air Power manufactured air compressors should be operated on not more than a 50% duty cycle. This means an air compressor that pumps air more than 50% of one hour is considered misuse, because the air compressor is undersized for the required air demand.
  • Page 7 DESCRIPTION OF OPERATION decrease pressure. To avoid minor readjustment after Air Compressor Pump: To compress air, the piston making a change in pressure setting, always approach moves up and down in the cylinder. On the downstroke, the desired pressure from a lower pressure. When air is drawn in through the air intake valves.
  • Page 8 TROUBLESHOOTING GUIDE PERFORMING REPAIRS MAY EXPOSE VOLTAGE SOURCES, MOVING PARTS OR COM- PRESSED AIR SOURCES. PERSONAL INJURY MAY OCCUR. PRIOR TO A'n'EMPTING REPAIRS, UNPLUG THE COMPRESSOR AND BLEED OFF TANK AIR PRESSURE. PROBLEM CAUSE i CORRECTION Pressure switch does not shut off motor Excessive tank pressure- safety Move the pressure switch lever to the "OFF"...
  • Page 9 TROUBLESHOOTING GUIDE (Continued) PROBLEM CAUSE CORRECTION Air leak from safety valve Possible defect in safety valve Operate safety valve manually by pulling on ring valve still leaks, it should be replaced. Defective check valve. Knocking Noise Remove and clean, or replace. Compressor is not supplying Prolonged excessive use of air.
  • Page 10 PARTS LIST OUTLET PRESSURE GAUGE PRESSURE TANK PRESSURE GAUGE COMPRESSOR ASSEMBLY SWITCH SAFETY VALVE CHECK VALVE _(Not Shown) REGULATOR AIR TANK AIR HOSE (Not Shown) DRAIN VALVE AIR CHUCK PARTS AVAILABLE FOR THIS UNIT DESCRIPTION PART NUMBER AIR CHUCK ..........SSH-8 REGULATOR .........
  • Page 11 SERVICE NOTES...
  • Page 12 Ioundonthe loll label onthe rear (ASMEcodecompressor only) air tank. of the air tank. is locatedonthe metaldata platewhichis weldedonto the backsideofthe air tank Model Code DeVilbiss Ai_ Power Company . 213 Industrial Drive • Jackson, TN 38301-9615...