Kenmore Top-Mount Refrigerator Use & Care Manual page 23

Hide thumbs Also See for Kenmore Top-Mount Refrigerator:
Table of Contents

Advertisement

Available languages

Available languages

PRODUCT DATA SHEETS
Base Grille Water
Filtration
System
Model WF-LC200V Capacity 200 Gallons (757 Liters)
Model WF-NLC120V Capacity 120 Gallons (454 Liters)
System tested and certified by NSF International against NSF/ANSI
Standard 53 for the reduction of Lead, Mercury, Benzene,
p-dichlorobenzene,
Cysts, Turbidity, Asbestos, Endrin,
O-Dichlorobenzene,
Toxaphene, Ethyl Benzene, 1,2,4-trichlorobenzene
and against NSF/ANSI Standard 42 for the reduction of Chlorine Taste
and Odor and Particulate Class I.
This system has been tested according to ANSl/NSF 42/53 for the reduction of the substances
listed below. The concentration
of
the indicated substances
in water entering the system was reduced to a concentration
less than or equal to the permissible limit for
water
leaving
the system,
as specified
in ANSl/NSF
42/53.
Substance
Reduction
NSF Reduction
Average
Influent Challenge
Maximum
Average
Minimum %
Average %
Aesthetic
Effects
Requirements
Influent
Concentration
Effluent
Effluent
Reduction
Reduction
Chlorine Taste/Odor
_>50%
1.9 mg/L
2.0 mg/L _+10%
| 0.12 mg/L
0.08 mg/L
>75%
>75%
Part cu ate C ass
_>85%
5,300,000/mL
At east 10,000 part c es/m 4 50,000/mL**
15,725/mL
99.0%
99.7%
Contaminant
NSF Reduction
Average
Influent Challenge
Maximum
Average
Minimum %
Average %
Reduction
Requirements
Influent
Concentration
Effluent
Effluent
Reduction
Reduction
Lead: @ pH 6.5
0.01mg/L
0.14 mg/U
0.15 mg/L _+10%
0.001 mg/L
0.001 mg/L
99.29%
99.29%
Lead: @ pH 8.5
0.01 mg/L
0.15 mg/L t
0.15 mg/L
_+10%
0.001 mg/L
0.001 mg/L
99.32%
99.32%
Mercury: @ pH 6.5
0.002 mg/L
0.0058 mg/L
0.006 mg/L _+10%
0.0005 mg/L
0.0003 mg/L
91.37%
94.82%
Mercury: @ pH 8.5
0.002 mg/L
0.0055 mg/L
0.006 mg/L
_+ 10%
0.0013 mg/L
0.0005 mg/L
76.36%
90.90%
Benzene
0.005 mg/L
0.0153 mg/L
0.015 mg/L _+ 10%
0.0036 mg/L
0.0014 mg/L
76.47%
90.84%
p-dichlorobenzene
0.075 mg/L
0.215 mg/L
0.225 mg/L _+ 10%
0.0037 mg/L
0.0010 mg/L
98.27%
99.52%
Asbestos
99.0%
842 x 107
107to 10_fibers/L tt
1.6 x 107 mg/L
1.6 x 107 mg/L
99.81
99.81%
Cysts _
99.95%
165,500/mL
5O,00O/L min.
1 mg/L
1 mg/L
99.99%
99.99%
Turbidity
0.5 NTU
11.75 NTU
11 _+1 NTU
0.38 NTU
0.22 NTU
96.76%
98.12%
Endrin
0.002
0.0056
0.006 _+10%
0.0007
0.0004
87.50
92.85
O-Dichlorobenzene
0.60
1.84
1.8 _+10%
0.33
0.071
82.06
96.14
Toxaphene
0.003
0.0143
0.015 _+10%
0.001
0.001
93.00
93.00
Ethyl Benzene
0.70
2.00
2.1 _+10%
0.60
0.169
70.00
91.55
1,2,4- trichlorobenzene
0.07
0.232
0.21 _+10%
0.0025
0.0007
98.92
99.69
Test Parameters: pH = 7.5 + 0.5 unless otherwise noted. Flow
(17.2°C).
It is essential that operational,
maintenance, and filter
replacement requirements be carried out for the product to
perform as advertised.
Model WF-LC2OOV: The filter monitor system measures the
amount of water that passes through the filter and alerts you
to replace the filter. When 90% of the filter's rated life is used,
the filter indicator light changes from green to yellow. When
100% of the filter's rated life is used, the filter indicator light
changes from yellow to red, and it is recommended
that you
replace the filter. Use replacement cartridge LC200V/
NLC120V, part #9915. 2006 suggested retail price of $32.99
U.S.A./S49.99 Canada. Prices are subject to change without
notice.
Model WF-NLC120V: Change the water filter cartridge every
6-9 months. Use replacement cartridge LC200V/NLC120V,
part #9915. 2006 suggested retail price of $32.99 U.S.A./
$49.99 Canada. Prices are subject to change without notice.
The product is for cold water use only.
Do not use with water that is microbiologically
unsafe or of
unknown quality without adequate disinfection
before or after
the system. Systems certified for cyst reduction may be used
on disinfected waters that may contain filterable cysts.
*Class I particle size: >0.5 to <1 um
**Test requirement is at least 100,000 particles/mL of AC Fine Test Dust.
= 0.5 gpm (1.9 Lpm). Pressure = 60 psig (413.7 kPa). Temp. = 63°F
Refer to the front cover
or "Accessories"
section
for the
Manufacturer's
name,
address
and telephone
number.
Refer to the "Warranty"
section
for the Manufacturer's
limited
warranty.
Application
Guidelines/Water
Supply
Parameters
Water Supply
City or Well
Water Pressure
30 - 120 psi (207 - 827 kPa)
Water Temperature
33 ° - 100°F (0.6 ° - 37.8°C)
Service
Flow Rate
0.5 GPM (1.89 L/min.)
@ 60 psi.
tThese contaminants
are not necessarily in your water supply. Performance
may vary based on local water conditions.
ttFibers greater than 10 um in length
_Based on the use of Cryptosporidium
parvum oocysts
_ NSF is a registered trademark
of NSF International.
23

Advertisement

Table of Contents
loading

Table of Contents