Sanyo CHDXR09663* Service Manual page 105

2-way eco-i multi system
Hide thumbs Also See for CHDXR09663*:
Table of Contents

Advertisement

2. Detailed Settings Function
(Continued from previous page)
Item code
3C
3d
3E
40
45
46
5d
5E
5F
60
4
62
Item
Heat exchanger temperature for
cold air discharge
Fan output switching
Drain pump delayed start time
Humidifier drain pump setting
DC flap operation mode
DC flap swing mode
DC fan tap setting
Humidifier ON time
Stop at time set for OFF timer after
operation starts
Timer function change prohibit
Smudging control
Description
The heat exchanger temperature control point for prevention of cold air
discharge during heating operation can be changed.
The indoor unit PCB optional output for the fan can be switched
according to the purpose of use.
The drain pump starts after the set time delay after cooling operation
stops.
This specifies the humidifier and drain pump setting.
Changes flap operation to draft reduction mode.
Selects the swing operation mode for the flap.
Sets the DC fan tap according to the purpose of use.
Change the settings data at the same time.
Sets the humidifier output ON time for when the humidifier is operating.
ON/OFF control is performed during humidifier operation.
This setting therefore sets the ON time per 60-second interval.
This setting enables a function that stops operation when the amount
of time set for the OFF timer has passed after remote controller
operation was started.
This function prohibits changes from being made to the remote
controller time setting.
Smudging control is disabled when 0000 is set.
4 - 14
W-2WAY ECO-i SYSTEM
Remote Controller Functions

Hide quick links:

Advertisement

Table of Contents
loading