Replacing T He Manifold/Burner Assembly - Kenmore 153.336340 Owner's Manual

Mobile home gas water heater
Table of Contents

Advertisement

Replacing
the Manifold/Burner
Assembly
Explosion Hazard
Tighten both manifold
door screws securely.
Remove any fiberglass
between
gasket
and combustion
chamber.
Replace viewport if glass is missing or
damaged.
Replace manifold component block if missing
or removed.
Replace door gasket if damaged.
Failure to follow these instructions can result
in death, explosion, or fire.
8.
9.
10.
11.
tube, locate the one provided with your parts kit. Install it in
the gas control valve/thermostat
at the pilot location, hand
tight only.
Next, insert the pilot tube into the ferrule nut until it bottoms
out. NOTE: Hold the tube in this position. Tighten the ferrule
nut with a wrench until the crimp connection seals to the
pilot tube. Continue to tighten until the nut is tight in the gas
control valve/thermostat.
Finally, start the thermocouple
nut
and turn it all the way in by hand. An additional quarter turn
with a 3/8" open-end wrench will then be sufficient to seat
the lockwasher. When you are finished, connect the two
wire leads that go to the thermal switch.
Reconnect the igniter wire.
Turn gas supply on and refer to the Lighting Instructions.
With the burner tit, check the gas control valve/thermostat
supply
line, manifold
component
block,
manifold
tube,
and pilot tube connections
for leaks. Check for leaks by
brushing
on an approved
noncorrosive
leak detection
solution. Bubbles forming indicate a leak. Correct any leak
found. IMPORTANT: All leaks must be fixed immediately.
Replace the outer door.
FLAMEARRESTOR
BRACKET
2.
3.
4.
5.
6.
Before
you proceed,
verify
that you are installing
the
correct manifold/burner
assembly for the type of gas that
your water heater will use (natural gas or L.P. gas). NOTE:
If you are converting
your unit, the gas control valve/
thermostat must also be set to use the correct type of gas.
For instructions, refer to your manual or to the label on the
front of your water heater.
Check the door gasket for damage or imbedded
debris
prior to installation.
Inspect the view port for damage and replace as required.
Insert
the
manifold/burner
assembly
into the
burner
compartment,
making sure that the tip of the manifold tube
engages in the slot of the bracket inside the combustion
chamber (Figures 37 & 38).
Inspect
the door gasket
and
make sure
there
is no
fiberglass
insulation
between
the
gasket
and
the
combustion chamber.
Replace
the two screws,
which
secure
the manifold/
burner assembly
door to the combustion
chamber
and
tighten securely. Once the manifold/burner
assembly door
is tightened,
visually
inspect
the door gasket between
the manifold/burner
assembly
door and the combustion
chamber for spaces or gaps that would prevent a seal.
IMPORTANT:
Do not operate the water heater if the door
gasket does not create a seal between the manifold door
and the combustion chamber.
During the following
procedure,
do not cross-thread
or
apply any thread sealant to any of the fittings listed below.
First, reconnect the manifold tubing to the gas control valve/
thermostat.
NOTE: If a ferrule nut needs to be installed for the pilot
32
TIP
FIGURE 37.
TIP
MANIFOLD
TUBE
CLOSE-UP
INSIDE
VIEW
OF
THE
COMBUSTION
CHAMBER.
__SLOT
BRACKET
FIGURE 38.

Hide quick links: