6.
Position the new thermocoupte through the bottom opening
of the two piece wire connector (Figure 34). Be sure igniter
wire is positioned
through the small opening
of the two
piece wire connector.
7.
Re-attach
the burner. Note the orientation
of the burner
(Figure 33.)
8.
See "Replacing the Manifold/Burner
Assembly."
FERRULE
NUT
THERMOCOUPLE
MANIFOLD
TUBE
TWO
PIECE
WIRE
CONNECTOR
...........
(_,_ i_;
Li
IGNITER
WIRE
PILOT
PILOT
BRACKET
__
_
OTHER
FITTINGS
',-=_
'_ ....
NOT SHOWN
R CLARITY
:'
=i
RETAINER
RLETpAIN|
'
CLiP
PILOT
TUBE
_
MANIFOLD/BURNER
DOOR
OPENING
Replacing
the Pilot/Pilot
Tube Assembly
Remove the manifold/burner
assembly.
See "Removing
the Manifold/Burner
Assembly."
2.
Lift the retainer clip straight up from the back of the two
piece wire connector (using a flat-blade screwdriver), then
remove the two piece wire connector
from the manifold
door (Figure 34.)
IMPORTANT: Be careful not to bend or alter the position of the
pilot tube.
It will be used as a bending template for the new
pilot assembly.
3.
Take off the burner by removing the two (2) screws located
underneath the burner. See Figure 33.
4.
Remove and keep the screw securing the pilot assembly to
the pilot bracket. (Figure 36)
5.
Remove and keep the old pilot tube and thermocouple.
6.
Using the old pilot tube as a guide, bend the new pilot tube
to match the old one. NOTE: Make only the bends closest
to the pilot before going to the next step. (Figure 36)
OLD
PILOT
ASSEMBLY
PILOT
TUBE
SCREW
OTHER FITTINGS
NOT SHOWN
FOR CLARITY
7.
8.
g.
10.
11.
12.
13.
14.
15.
Route the new pilot tube, thermocoupte,
and igniter wire
through the manifold/burner
door opening. (Figure 34)
Connect the new pilot tube and tighten the nut securing it
to the pilot assembly. IMPORTANT: Keep the pilot orifice in
the pilot when making the connection.
Do not operate the
water heater without the pilot orifice installed.
Install the thermocoupte, making sure that it isfully seated.
Re-attach the pilot assembly to the pilot bracket and secure
using the screw removed earlier.
Re-attach
the burner. Note the orientation
of the burner
(Figure 33).
Position the new pilot tube through the largest opening of
the two piece wire connector.
NOTE: The largest opening
should
be located at the top position.
The igniter wire
should be located in the middle opening and thermocouple
in the bottom opening (Figure 37).
THERMOCOUPLE
\\
TWO PIECE WIRE CONNECTOR
FIGURE 37.
Reposition
the two piece wire connector
in the manifold
door opening and secure it with the retainer clip.
Carefully
bend the new pilot tube and thermocoupte
to
match the bend of the manifold tube. NOTE: When bending,
DO NOT crimp or crease the pilot tube or thermocouple.
(Figure 34)
Before you proceed to the next step, install the new brass
ferrule nut in the gas control valve/thermostat's
pilot tube
opening. HAND TIGHTEN ONLY.
16. See "Replacing the Manifold/Burner
Assembly."
Cleaning
the Combustion
Chamber
and
Flame-arrestor
1.
2.
Follow
procedure
outlined
in "Removing
the Manifold/
Burner Assembly."
Use a vacuum cleaner/shop vac to remove all loose debris
in the combustion
chamber (Figure 38). Use compressed
air to clear any dust or debris that may have accumulated
in the flame-arrestor.
COMBUSTION
CHAMBER
IGNITER
WIRE
THERMOCOUPLE
FIRST
BEND(S)
FIGURE 36.
3O
FIGURE 38.
3.
Reassemble
by following the procedure under "Replacing
the Manifold/Burner
Assembly."