Housekeeping
Vacuum around base of water heater for dust, dirt, and lint on
a regular basis.
Fire and Explosion
Hazard
Do not obstruct combustion
air
openings
at the bottom of the
water heater.
Do not use or store flammable
vapor products such as gasoline,
solvents or adhesives
in the
same room or area near water
heater or other appliance.
At least annually, check the
base-ring filter and flame arrester
for any dust, lint, or debris that
may have accumulated.
Clean
as necessary.
Can cause serious injury or death.
AT LEAST
ANNUALLY,
A VISUAL
INSPECTION
SHOULD
BE
MADE
OF THE BASE-RING
FILTER
AND FLAME
ARRESTER.
CLEAN
IF LINT ACCUMULATIONS
ARE NOTICED.
INSTALLED IN SUITABLEAREA:
To ensure sufficient ventilation
and combustion
air supply, proper clearances from the water
heater must be maintained.
See "Installation
Instructions."
Combustible
materials such as clothing, cleaning materials, or
flammable liquids, etc. must not be placed against or adjacent
to the water heater because they could catch on fire.
Anode
Rod Inspection
Property
Damage
Hazard
• Avoid water heater damage.
• Inspection and replacement of anode rod required.
The anode rod is used to protect the tank from corrosion.
Most hot water tanks are equipped with an anode rod.
The
submerged
rod deteriorates
to protect the tank.
Instead of
corroding the tank, water ions attack and eat away the anode
rod. This does not affect the water's taste or color.
The rod
must be maintained to keep the tank in operating condition.
Anode
deterioration
depends
on water
conductivity,
not
necessarily
water condition. A corroded
or pitted anode rod
indicates high water conductivity and should be checked and/
or replaced more often than an anode rod that appears to be
intact. Replacement
of a depleted anode rod can extend the
life of your water heater. Inspection should be conducted by
calling the Sears Service Center for an authorized
contractor.
At a minimum, the anode(s) should be checked annually after
the warranty period.
Anode Rod Depletion
i
I|
Exposed
|p--Support
LI
Wire
Pitted ._
"1_
Anode _
_?,_l
Expose
Support_l
Wire
u
FIGURE 27.
Temperature-Pressure
Relief Valve Operation
The temperature-pressure
relief
valve must
be
manually
operated at least once a year.
r!11 mT_, ,'[€-1 =I
• Burn hazard
• Hot water discharge.
• Keep
clear of relief valve
discharge outlet.
When checking the temperature-pressure
relief valve operation,
make sure that (1) no one is in front of or around the outlet of
the temperature-pressure
relief valve discharge
line, and (2)
that the water discharge will not cause any property damage, as
the water may be extremely hot. See Figure 28.
TEMPERATURE-PRESSURE
RELIEF
VALVE
DISCHARGE
PIPE
FIGURE 28.