Analog Outputs; Powertools Pro; Watch Window - Emerson SM-EZMotion Module P/N 400361-00 User Manual

Table of Contents

Advertisement

Error Code
Cause
(x.50)
Trip?
172
Y
173
Y
174
Y
File Corruption Error - Consult Factory
175
Y

13.2 Analog Outputs

The Unidrive SP has two Analog Outputs that can be
configured to represent any base drive parameter (00.00 -
21.51). The default configuration for the two drive analog
outputs are Speed Feedback (3.02) and Active Current
(4.02). Using this method will automatically update the
analog output value.
To configure the drive Analog Output to represent an
Figure 113:
Analog Output Example
For more details on the Analog Output of the drive, refer to
the Unidrive SP User Guide or Advanced User Guide.

13.3 PowerTools Pro

13.3.1 Watch Window

PowerTools Pro contains a diagnostic utility called the
Watch Window. The Watch Window can be used while
PowerTools Pro is online with the SM-EZMotion module.
120
Error
Invalid Slot 2 Selection
Invalid Slot 3 Selection
Module Output Overload
Menu 7
7.01
EZMotion Program 0
7.02
7.03
Var.Var0 = 12.34
7.04
Do While TRUE
7.05
Menu.20.21 = Var.Var0
7.06
Loop
7.07
7.08
7.09
7.10
7.11
7.12
7.13
7.14
7.15
7.16
7.17
7.18
7.19
20.21
7.20
www.emersonct.com
Possible Reason
Option module selected for Slot 2 in
PowerTools Pro file does not match
actual module type fitted
Option module selected for Slot 3 in
PowerTools Pro file does not match
actual module type fitted
SM-EZMotoin module can only supply
20mA maximum total output current. If
this fault occurs, the digital output
device attached to the module outputs
is drawing too much current.
SM-EZMotion module parameter, the Analog Output
Source of the drive (7.19 or 7.22) must be set to a drive
parameter in Menu 20 (20.21 through 20.40). Menu 20
parameters 21 through 40 must be used because they are
32-bit parameters. Once the Analog Output Source has
been set to a 32-bit parameter, the SM-EZMotion user
program must be coded to write the value of the desired
SM-EZMotion parameter to the 32-bit menu parameter.
Below is an example of this process.
Menu 20
20.15
20.16
20.17
20.18
20.19
20.20
20.21
12.34
20.22
20.23
20.24
20.25
20.26
20.27
20.28
20.29
20.30
20.32
20.33
20.34
The Watch Window allows the user to monitor the status of
all of their desired system parameters in one location. An
example of the Watch Window is found in Figure 114.
Possible Solution
Switch module located in Slot 2 to match
module type selected in PowerTools Pro
file. Alternatively, update the PowerTools
Pro configuration to match the module
type actually fitted, and then re-download
the configuration.
Switch module located in Slot 3 to match
module type selected in PowerTools Pro
file. Alternatively, update the PowerTools
Pro configuration to match the module
type actually fitted, and then re-download
the configuration.
Modify circuitry of devices connected to
the SM-EZMotion module digital outputs
so that they draw no more than 20mA
total.
Anaolg Output Value
12.34
SM-EZMotion Module User Guide