Model P6GEG2KL, P6KG2KL, P6WG2KL Capacity 2000 Gallons (7571 Liters)
This system has been tested according to NSF/ANSI Standards 42 for the reduction of the substances listed below. The
concentration of the indicated substances in water entering the system was reduced to a concentration less than or equal to the
permissible limit for water leaving the system, as specified in NSF/ANSI Standards 42.
Substance Reduction
NSF Reduction
Aesthetic Effects
Requirements
Chlorine Taste/Odor
50% reduction 1.9727 mg/L 2.0 mg/L ± 10%
Test Parameters: pH = 7.5 ± 0.5 unless otherwise noted. Flow = 0.50 gpm (1.89 Lpm). Pressure = 60 psig (413.7 kPa).
Temp. = 68°F to 71.6°F (20°C to 22°C). Rated service capacity = 2000 gallons (7571 liters).
It is essential that operational, maintenance, and filter
replacement requirements be carried out for the product to
perform as advertised.
Use replacement filter P6RFWG2K, P6RFGEG2K,
P6RFKG2K, Part Number ICE2.
Style 1 – When the water filter status display changes from
"GOOD" to "ORDER," order a new filter. When the filter
indicator reads "REPLACE," it is recommended that you
replace the filter.
Style 2 – Press FILTER to check the status of your water filter.
If the filter indicator light is yellow and the words "ORDER
FILTER" appear on the display screen, order a new filter. If the
filter indicator light is red, it is recommended that you replace
the filter.
These contaminants are not necessarily in your water supply.
While testing was performed under standard laboratory
conditions, actual performance may vary.
The product is for cold water use only.
Do not use with water that is microbiologically unsafe or of
unknown quality without adequate disinfection before or after
the system.
® NSF is a registered trademark of NSF International.

PERFORMANCE DATA SHEET

Ice Maker Water Filtration System
Average
Influent
System tested and certified by NSF
International against NSF/ANSI
Standard 42 for the reduction of
Chlorine Taste and Odor.
Influent Challenge
Maximum
Concentration
Effluent
0.71 mg/L
Refer to the "Warranty" section for the Manufacturer's name,
address and telephone number.
Refer to the "Warranty" section for the Manufacturer's limited

warranty.

Application Guidelines/Water Supply Parameters
Water Supply
Water Pressure
Water Temperature
Service Flow Rate
Average
Minimum %
Effluent
Reduction
0.7788 mg/L
70.2
City or Well
30 - 120 psi (207 - 827 kPa)
33°- 100°F (0.6° - 37.8°C)
0.50 gpm (1.89 Lpm) @ 60 psi
Average %
Reduction
72.81
19