CHAPTER 6 TROUBLESHOOTING

Problem
Possible cause
No power
The power switch was not
turned on.
The power cable was not
connected correctly.
——————————
Read operation
The documents were not
does not start.
placed on the ADF correctly.
The ADF was not closed
completely.
The interface cables were not
connected correctly.
Terminator was not con-
nected. (M3096GX).
Pictures and
Halftone processing was not
photographs are
selected.
not read cor-
The document bed, docu-
rectly.
ment holding pad, or inside
ADF is dirty.
Characters and
Simple binarization was not
lines are not
done.
read correctly.
The document bed, docu-
ment holding pad, or the
inside of the ADF is dirty.
Image is dis-
The document was moved
torted or un-
during the read operation.
clear.
The document was not in
contact with the glass.
If a problem occurs, use Table 6.1 to resolve the problem.
Table 6.1 Check items
Response
Press the power switch.
Connect the power cable correctly.
Turn off the power once and make an
attempt to turn on the power again. If the
power is not turned on, contact your
Fujitsu service representative.*
Insert the first a few pages into the slot.
Make sure that the ADF is closed com-
pletely.
Connect the interface cables correctly.
Connect the terminator.
Select a halftone mode from the host
system.
Clean the dirty parts as explained in
Section 5.3, "Cleaning."
Select a binarization mode from the host
computer.
Clean the dirty parts as explained in
Section 5.3, "Cleaning."
Keep the document cover closed during
reading so that the document will not be
moved.
Adjust the document so that it is in
contact with the glass.
6 – 1