Diagnosing Problems Using Easy Led Diagnostics; Easy Led Diagnostics Leds - Lenovo ThinkServer RD120 Installation Manual

(english) installation guide
Hide thumbs Also See for ThinkServer RD120:
Table of Contents

Advertisement

Press the reset button to reset the server and run the power-on self-test (POST).
You might have to use a pen or the end of a straightened paper clip to press the
button.
The server is designed so that LEDs remain lit when the server is connected to a
power source but is not turned on, provided that the power supply is operating
correctly. This feature helps you to isolate the problem when the operating system
is shut down.

Diagnosing problems using Easy LED Diagnostics

LEDs in two locations on the server are available to help you diagnose problems
that might occur during installation. Use them in the following order:
1. Easy LED Diagnostics panel - Look at this panel first. If a system error has
2. LEDs on the system board - To identify the component that is causing the

Easy LED Diagnostics LEDs

The following table describes the LEDs on the Easy LED Diagnostics panel, the
problems that they indicate, and actions to solve the problems.
v Follow the suggested actions in the order in which they are listed in the Action column until the problem
is solved.
v See the parts listing in the Hardware Maintenance Manual to determine which components are customer
replaceable units (CRU) and which components are field replaceable units (FRU).
v If an action step is preceded by "(Trained service technician only)," that step must be performed only by a
trained service technician.
LED
Description
None, but
An error has occurred and cannot be
the
diagnosed, or the Advanced System
system-
Management (ASM) processor on the
error LED
Remote Supervisor Adapter II SlimLine
is lit.
has failed. The error is not represented
by a Easy LED Diagnostics LED.
OVER
The power supplies are using more
SPEC
power than their maximum rating.
PS 1
The power supply in bay 1 has failed.
64
ThinkServer RD120 Types 6444, 6445, 6446, and 6447: Installation Guide
occurred, the system-error LED on the front of the Easy LED Diagnostics
drawer is lit. Slide the latch to the left on the front of the operator information
panel to access the Easy LED Diagnostics panel. Note any LEDs that are lit,
and then close the drawer.
error, note the lit LED on or beside the component.
Action
Use the Configuration/Setup Utility program to check the
system-error log for information about the error.
1. Remove optional devices from the server.
2. Replace the failing power supply.
Attention:
personnel other than Lenovo service technicians are authorized
to connect or disconnect power to the dc power supply and to
remove and install a dc power supply. See the documentation
that comes with each dc power supply.
1. Make sure that the power supply is correctly seated.
2.
Attention:
In a dc power environment, only trained
service personnel other than Lenovo service technicians are
authorized to connect or disconnect power to the dc power
supply and to remove and install a dc power supply. See
the documentation that comes with each dc power supply.
In a dc power environment, only trained service
Replace the failed power supply.