Memory Mirroring - Lenovo ThinkServer RD120 Installation Manual

(english) installation guide
Hide thumbs Also See for ThinkServer RD120:
Table of Contents

Advertisement

10. Replace the DIMM air baffle.
11. Replace the riser-card assembly.
If you have other optional devices to install, do so now. Otherwise, go to
"Completing the installation" on page 29.

Memory mirroring

You can configure the server to use memory mirroring. Memory mirroring stores
data in two pairs of DIMMs simultaneously. If a failure occurs, the memory controller
1
DIMM air baffle
2
Riser card assembly
4. Remove the riser-card assembly.
5. Remove the DIMM air baffle.
6. Open the retaining clip on each end of the DIMM connector.
7. Touch the static-protective package that contains the DIMM to any unpainted
metal surface on the outside of the server. Then, remove the DIMM from the
package.
8. Turn the DIMM so that the keys align correctly with the connector.
9. Insert the DIMM into the connector. Firmly press the DIMM straight down into
the connector. The retaining clips snap into the locked position when the DIMM
is firmly seated in the connector.
Note: If there is a gap between the DIMM and the retaining clips, the DIMM
has not been correctly inserted; open the retaining clips, remove the DIMM,
and then reinsert it.
3
Finger hole
4
Release ring
Chapter 2. Installing optional devices
13

Advertisement

Table of Contents
loading

Table of Contents