Smart Error Log Data Format - Fujitsu MPE3XXXAE Product Manual

Fujitsu computer drive user manual
Table of Contents

Advertisement

Error logging capability
Bit 0: Indicates that error logging function.
Bits 1 to 7: Reserved bits
Check sum
Two's complement of the lower byte, obtained by adding 511-byte data one byte at a time
from the beginning.
Insurance failure threshold
The limit of a varying attribute value. The host compares the attribute values with the
thresholds to identify a failure.
If an unrecoverable error is detected during execution of a command received by the device
from the host computer, the device saves the SMART error log on the disk medium.
The host computer can issue the SMART Read Log Sector sub-command (FR register = D5h,
SN register = 01h) and read the SMART error log.
Byte
00
Error log version number
01
The most recent "Error Log" point
02 to 31
Error Log Data
Structure 1
32
33
34
35
36
37
38
39
3A to 3D
3E
3F
40
41
42
43
44
5 - 56
Table 5.11 SMART error log data format (1/2)
Reserved
Command Data
Structure
Error Data
Structure
C141-E093-01EN
Item
Device Control register
Features register
Sector Count register
Sector Number register
Cylinder Low register
Cylinder High register
Device/Head register
Command register
Elapsed time [ms] from the point when the
power is turned on until command reception
Reserved
Error register
Sector Count register
Sector Number register
Cylinder Low register
Cylinder High register
Device/Head register

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mpe3043aeMpe3084aeMpe3173ae

Table of Contents