Table 5.29 FEATURE CONTROL COMMAND
Byte(hex)
Name
00, 01
Action Code
Function
02, 03
Code
04, 05
Feature Code
06, 07
New State
08, 09
Option Flag
0A to 1FF
(Reserved)
C141-E280
Value
0004h
FEATURE CONTROL COMMAND
0001h
Set New State
Return Current State
0002h
Current Feature Control State is displayed in SN/SC
field.
Return Option Flag
0003h
Current Option Flag is displayed in SN/SC field.
0001h
Write Cache
0002h
Write Reordering
0003h
Set time interval for temperature logging
Feature Code = 0001h (Set Write Cache)
0001h: Allow write cache operation to be determined
by ATA Set Feature command.
0002h: Force Write Cache enabled.
0003h: Force Write Cache disable.
Feature Code = 0002h(Set Write Reordering)
0001h: Enable Write Reordering
(2 byte)
0002h: Disable Write Reordering
Feature Code = 0003h(Set time interval)
0000h:
0001h-FFFFh: Logging interval in minutes
(ex.) 0001h:
000Fh:
Bit 15-1: Reserved
Bit0: 1 =
(2 byte)
COMRESET/Power cycle.
0 =
COMRESET/Power cycle.
-
Reserved
5.3 Host Commands
Description
Invalid
Temperature data collection
interval is 1min.
Temperature data collection
interval is 15min.
Maintain the state at
Revert to default setting at
5-79