T
ROUBLESHOOTING
•
30
Select the desired function by pressing the reset button. Hold the
button until the LEDs change to the next configuration.
Link LED Activity LED
OFF
OFF
OFF
ON
OFF
ON
(The function changes to the next in sequence every time the
reset button is pressed.)
Control Mode will automatically terminate if the AP/Bridge does
not detect the reset button has been pressed for approximately 3
seconds. At that point it will flash both LEDs twice, indicating it
is proceeding with the boot.
No Action; will boot normally
ON
Revert to Factory Default settings.
Force boot from Primary code image.
ON
No Action; will boot normally
Action