Hi-Limit Check - Frymaster Computer M2000 Operation Manual

Frymaster m2000 computer operation manual
Hide thumbs Also See for Computer M2000:
Table of Contents

Advertisement

Quick Reference For Programming Codes

Hi-Limit Check

1. Press
2. Computer displays OFF.
3. Press
*Note: For left-
4. CoDE shows in the left display.
side use 8888
and the left 1 &
2 buttons)
5. Press
6. HI-LIMIT shows in the right display.
7. Press and hold
8. Fryer will call for heat and
9. Right display will alternate between HI-limit and the
10. Heat is turned off now and hi-1 test is complete.
11. Press and hold right
12. The display will alternate between Hi-Limit and the
13. Press
14. Failure of the Hi-Limit 2 test is indicated by an alternating display
.
.
9
9
9
YZ-
YZ-
YZ-
side of split pot. Note: The test can only be conducted with the oil
above 180°F (82°C). If the shortening temperature is below 180°F
(82°C), the computer will display TOO COLD.
1
temperature until shortening reaches 410°F (210°C). Then the
display changes, alternating between Hi-1 and the temperature.
temperature display until the hi-limit opens. The display will
show Hi-2.
to clear test and turn computer off.
of HI-2 and BAD. Call for service immediately if this occurs.
8-4
9
YZ-
(9999*) for full vat or right
right cook channel key.
illuminates.
2
, which starts Hi-Limit 2 test.