MASTER JET CF SERIES ATMOSPHERIC GAS FRYERS

1.5 Cleaning Gas Valve Vent Tube

1. Carefully unscrew the vent tube from the gas valve. NOTE: The vent tube may be straightened
for ease in removal.
2. Pass a piece of ordinary binding wire (.052 inch diameter) or equivalent through the tube to
remove any obstruction.
3. Remove the wire, and then blow through the tube to ensure it is clear.
4. Reinstall tube and bend it so that the opening is pointing downward.

1.6 Adjusting Burner Ceramic Target Spacing and Alignment

Drain the frypot or remove the handle from the drain valve before proceeding further.
Proper spacing of the top edge of the burner ceramic targets is ¾-inch (13 mm) from the frypot side
[The rear target should be adjusted to 1-inch (25 mm) from the frypot back]. To adjust target
spacing, bend the brackets to which they are attached away or toward the frypot to the proper
distance. (A length of board of the proper thickness is useful as a gauge to verify spacing and
alignment.)
There should be about 3/4-inch spacing between the top edge of the targets
and the side of the frypot, and 1-inch between the rear target and the frypot
back.
CHAPTER 1: SERVICE PROCEDURES
DANGER
1-inch
3/4-inch
1-7