Example
Description

Lamp and Touch Switch Display (Number Specification)

Format
Description
Reference
Enquiry of the Display Status Use the following command to enquire whether a lamp or touch switch is displayed

Lamp and Touch Switch Display Status Enquiry

Format
Bit ON: The lamp or touch switch is turned on (or caused to flash).
Bit OFF: The lamp or touch switch is turned off.
To turn on lamps and touch switches with the numbers 1, 5, 6, 7, and 26
m0
m0
m1
m1
m2
m2
1
2
1
2
1

Changes the display status of the lamps or touch switches.

Whether the lamp or touch switch which corresponds to the specified bit is
turned on or flashes is determined by the setting made using the support tool.
[ESC]
1B
m
:
Display status
1
m
1
0 (30
)
H
1 (31
)
H
2 (32
)
H
3 (33
)
H
n
n
n
: Lamp or touch switch address (3-digit hexadecimal)
1
2
3
000 to 0FF
(0 to 255)
H
Changes the lamp or touch switch lighting status.
Specify the display status as 3 (all not lit) to turn off all the lamps and touch
switches. In this case, specify the lamp or touch switch number to any number in
the permitted range.
The display attributes set with the Support Tool determine if lamps #0 to #111 light
continuously or flash. The display status set with this command is ignored.
continuously lit or flashing by specifying its number.
n
n
n
: Lamp or touch switch address (3-digit hexadecimal)
1
2
3
000 to 0FF
(0 to 255)
H
m3
m3
m13
m13
=
2
1
2
1
2
E200000400000000000000000000
Q
m
n
1
1
 
 
51
Display Status
Not lit (normal display)
Lit
Flashing inverse
All not lit
[ESC]
R
n
n
1
2
 
 
1B
52
Section 6-2
n
n
2
3
 
 
n
3
 