Download Print this page

Valcom V-9941A User Manual page 7

One zone handsfree talkback control unit

Advertisement

Problem
1. No talk battery on Tip and
Ring
2. No paging at speaker
3. Paging at speaker but no
reply from speaker
Tip (1)
Ring (2)
SW3
Battery Feed
Gnd Start (5)
Inhibit (10)
-24Vdc (4)
Ground (3)
TROUBLESHOOTING CHART
a. Verify good connections on terminals 1 (TIP), 2 (RING), 3 (GND),
and 4 (-24VDC). Verify SW3 in "ON" position.
a. Test system with two Lineman's Test sets:
a.
Disconnect TIP and RING of the V-9941A from the telephone
system.
b.
Connect one test set across terminals 1 (TIP) and 2 (RING) of the
V-9941A and the second test set across terminals 6 (SPKR) and 7
(SPKR). Turn SW3 "ON".
c.
While monitoring the second test set, go off hook on the first test
set and page.
d.
If the page is heard when the V-9941A is working, verify the
connections to the speakers. If your system still does not work,
verify proper programming of your phone system. There should not
be any type of toll restriction on the port used to access the Valcom
equipment.
a. Verify talkback speakers are being used.
(NOTE: Most page ports are not talkback compatible)
Battery Feed
Loop Detect
Control
Circuit
Music Relay
Power
Supply
SIMPLIFIED SCHEMATIC
NOTE: Specifications are subject to change without notice.
Possible Solution
Talkback
Amplifier
7
(6) Spkr
(7) Spkr
(8) Music
(9) Music

Advertisement

loading