Warning
To avoid electrical shock or arc blast, or personal
injury or damage to the Meter, use specified fuses
ONLY in accordance with the following procedure.
Follow Figure 6-1 and proceed as follows to replace
the Meter's fuse:
l
Switch off the Meter, disconnect the power cord and
remove all connections from the terminals.
l
Remove the fuse cover from the power socket at the
Meter's back, then remove the Fuse 3 by gently
prying one end loose, then take out from its bracket.
l
Use the coin to open the compartment at the case
top, then remove the Fuse 1 and 2 by gently prying
one end loose, then take out from its bracket.
l
Install ONLY replacement fuses with the identical
type and specification as follows and make sure the
fuse is fixed firmly in the bracket.
Fuse 1: 0.5A, 250V, fast type fuse, ø5×20mm
Fuse 2: 10A, 250V, fast type fuse, ø5×20mm
Fuse 3: 0.2A, 250V, fast type fuse, ø5×20m
52
Model UT804: OPERATING MANUAL
l
Rejoin the fuse cover and the power socket.
l
Rejoin the compartment and the case top and close
the compartment.
Replacement of the fuses is seldom required. Burning
of a fuse always results from improper operation.