In each range, the Meter has an input impedance of 10M . This loading effect
can cause measurement errors in high impedance circuits. If the circuit impedance
is less than or equal to 10k , the error is negligible (0.1% or less).
When DC voltage measurement has been completed, disconnect the connection
between the testing leads and the circuit under test, and remove the testing leads
away from the input terminals of the Meter.
C. AC Voltage Measurement (See figure 4)
AC Voltage measurement is an auto ranging measurement mode.
Note:
Follow the same procedure as the DC Voltage Measurement mode. When you
using UT206A to carry out the measurement, use SELECT button to switch
between ACV and DCV.