STINGER Specifications
Compatible
Refrigerants
Power
Compressor
Cooling
Protection
Pressure Ratings
Temperature
Case
Size / Weight
Certification
Refrigerant
Liquid Rate
3.53 lb/min
R-22
1.60 kg/min
2.67 lb/min
R-134A
1.21 kg/min
3.02 lb/min
R-410A
1.37 kg/min
STINGER
R-12, R-22, R-114, R-134a, R-401A, R-401B, R-401C, R-402A,
R-402B, R-404A, R-406A, R-407A, R-407B, R-407C, R-407D,
R-408A, R-409A, R-410A, R-411A, R-411B, R-412A, R-500,
R-502, R-507, R-509
• 110/120 VAC, 1 Phase, 50/60 Hz, 8 Amps
• 220 VAC, 1 Phase, 50/60 Hz, 4 Amps
¾ HP High Performance Oilless
Two Cooling Fans
High pressure cutoff at 550 psi. Compressor is protected by
circuit breakers and internal compressor thermal sensor.
Optional 80% tank full shutoff kit (P/N 2090-0091).
Low Side design pressure 450 PSI
High Side design pressure 550 PSI
Operating Range 32 to 104 °F (10 to 40 °C)
Blow-Molded, High Impact Polyethylene
Length
17"
Width
9.5"
Height
11"
Weight
24 Lbs.
Complies with UL1963 (not evaluated for automotive use)
Refrigerant Recovery Rates
Certified per ARI 740-95 & 740-98
Liquid Push-Pull
Rate
12.30 lb/min
5.58 kg/min
10.98 lb/min
4.98 kg/min
14.62 lb/min
6.63 kg/min
Vapor Rate
0.29 lb/min
0.13 kg/min
0.22 lb/min
0.10 kg/min
0.22 lb/min
0.10 kg/min
3
See label on
back of unit
Vacuum Level
(inches Hg)
>15
>15
>15
Need help?
Do you have a question about the High Performance Oilless Commercial Refrigerant Recovery Unit and is the answer not in the manual?