Electrical Rating Tables - Friedrich racservmn Service Manual

Friedrich air conditioner model number: racservmn
Table of Contents

Advertisement

Electrical Rating T

Electrical Rating Tables

Electrical Rating T
Electrical Rating T
Electrical Rating T
Model
ALL SV and XQ MODELS,
KS10J10, KS12J10B, KS15J10, RS10J10, RS12J10A,
RS15J10, SS08J10R, SS09J10C, SS10J10AR,
SS12J10AR, SS14J10R, SC06H10D,
EQ08J11, YQ06J10B, YS09J10B
KS12J30B, KM18J30C, RS16J30A,
RM18J30A, SS12J30D, SS16J30A, SM18J30BR
KM20J30, KM24J30, SM20J30,
SL25J30, SL28J30B*, ES12J33B,
ES16J33A, YS12J33
SL35J30, EM18J34B, EL25J35, EL35J35,
YM18J34B, YL24J35C
* Optional 30 Amp Kit (618-869-00) is recommended in 208 Volt power supply areas that fall below 208 Volts.
For more information, call the Friedrich Service Department.
Due to a program of continuing improvement, specifications are subject to change without notice.
Installation Notes:
Supply Cord - All with right angle plug 6' on 115V; 5' on 230/208V.
Room air conditioners include accessories for window or thru-the-wall installation.
TWINTEMP
®
models include accessories for thru-the-wall installation only.
Window mounting requires use of optional accessory kit as listed below:
MODEL
EQ08J11, YQ06J10B
ES12J33B, ES16J33A,
YS09J10B, YS12J33
EM18J34B, YM18J34B
EL25J35, EL35J35,
YL24J35C
Wire Size
Use ONLY wiring size recommended for
single outlet branch circuit.
Fuse/Circuit
Use ONLY type and size fuse or HACR
Breaker
circuit breaker indicated on unit's rating
plate. Proper
is the responsibility of the owner.
Grounding
Unit MUST be grounded from branch circuit
through service cord to unit, or through
separate ground wire provided on permanently
connected units. Be sure that branch circuit
or general purpose outlet is grounded.
Receptacle
The field supplied outlet must match plug on
service cord and be within reach of service
cord.
Do NOT alter the service cord or plug. Do
NOT use an extension cord. Refer to the table
above for proper receptacle and fuse type.
Circuit Rating
Breaker or T-D Fuse
125V - 15A
250V - 15A
250V - 20A
250V - 30A
KIT NO.
WIKQ
WIKS
WIKM
WIKL
current protection to the unit
ables
ables
ables
ables
Plug Face
Appearance
(NEMA#)
(Facing Blades)
5 - 15P
6 - 15P
6 - 20P
6 - 30P
Electric shock hazard.
Turn off electric power before service or installation.
All electrical connections and wiring MUST be installed by a qualified
electrician and conform to the National Electrical Code and all local
codes which have jurisdiction.
Failure to do so can result in property damage, personal injury and/
or death.
The consumer - through the AHAM Room Air Conditioner
Certification Program - can be certain that the AHAM
Certification Seal accurately states the unit's cooling and
heating capacity rating, the amperes and the energy efficiency
ratio.