Electrical Data Tables - Friedrich OES series Installation & Operation Manual

Wall-mount outdoor wall-mounted air conditioners / heat pumps
Hide thumbs Also See for OES series:
Table of Contents

Advertisement

Table 3 - Electrical Data
Air Conditioners
Factory
Voltage / Hz
Circuit
Breakers
1
230/208-60-1
OES18KA 00
2
230/208-60-1
05
2
230/208-60-1
08
2
230/208-60-1
10
1
230/208-60-1
OES24KA 00
2
230/208-60-1
05
2
230/208-60-1
08
2
230/208-60-1
10
1
230/208-60-1
OES30KA 00
2
230/208-60-1
05
2
230/208-60-1
08
2
230/208-60-1
10
2
230/208-60-1
15
1
230/208-60-1
OES36KA 00
2
230/208-60-1
05
2
230/208-60-1
08
2
230/208-60-1
10
2
230/208-60-1
15
1
230/208-60-1
OES42KA 00
2
230/208-60-1
10
2
230/208-60-1
15
1
230/208-60-1
OES48KA 00
2
230/208-60-1
10
2
230/208-60-1
15
1
230/208-60-1
OES60KA 00
2
230/208-60-1
15
3
230/208-60-1
20
If wire is applied at ambient greater than 30°C (86°F), consult Table 310-16 of the NEC (ANSI/NFPA 70). The ampacity of nonmetallic-sheathed cable (NM), trade name ROMEX,
1
shall be that of 60°C (140°F) conductors, per the NEC (ANSI/NFPA 70) Article 336-30. If other than uncoated (non-plated), 60°C or 75°C (140°F or 167°F) insulation, copper wire
(solid wire for 10 AWG and smaller, stranded wire for larger than 10 AWG) is used, consult applicable tables of the NEC (ANSI/NFPA 70).
Length shown is as measured 1 way along the wire path between the unit and the service panel for voltage drop not to exceed 10V, consult the factory for longer wire lengths if
2
needed.
Time-delay fuse, or HACR type breaker.
3
12
MCA
Voltage
/ Ph
Range
Ckt 1
198-253
15.0
198-253
15.0
198-253
15.0
198-253
15.0
198-253
19.9
198-253
19.9
198-253
19.9
198-253
19.9
198-253
22.8
198-253
22.8
198-253
22.8
198-253
22.8
198-253
22.8
198-253
27.9
198-253
27.9
198-253
27.9
198-253
27.9
198-253
27.9
198-253
31.8
198-253
31.8
198-253
31.8
198-253
41.0
198-253
41.0
198-253
41.0
198-253
48.0
198-253
48.0
198-253
48.0
920-138-02 (3-04)
Multiple Circuits
HACR / Max
Wire Size
Breaker Size
(field)
Ckt 2
Ckt 1
Ckt 2
Ckt 1
N/A
20
N/A
12
26.0
20
30
12
39.0
20
40
12
52.0
20
60
12
N/A
30
N/A
10
26.0
30
30
10
39.0
30
40
10
52.0
30
60
10
N/A
40
N/A
8
26.0
40
30
8
39.0
40
40
8
52.0
40
60
8
39.0
40
40
8
N/A
40
N/A
8
26.0
40
30
8
39.0
40
40
8
52.0
40
60
8
39.0
40
40
8
N/A
50
N/A
6
52.0
50
60
6
39.0
50
40
6
N/A
60
N/A
6
52.0
60
60
6
39.0
60
40
6
N/A
60
N/A
6
39.0
60
40
6
52.0/52.0
60
60/60
6
Groung Wire
MCA
Size (field)
Ckt 2
Ckt 1
Ckt 2
Ckt 1
N/A
12
N/A
15
10
12
10
28
8
12
10
41
6
12
10
53
N/A
10
N/A
19.9
10
10
10
28
8
10
10
41
6
10
10
53
N/A
10
N/A
22.8
10
10
10
29
8
10
10
42
6
10
10
55
8
10
10
81
N/A
10
N/A
27.9
10
10
10
29
8
10
10
42
6
10
10
55
8
10
10
81
N/A
10
N/A
31.8
6
10
10
55
8
10
10
81
N/A
10
N/A
41
6
10
10
55
8
10
10
81
N/A
10
N/A
48
8
10
10
83
6/6
10
10/10
N/A
Single Circuit
HACR
Groung
Wire
/ Max
Wire
Size
Breaker
Size
(field)
Size
(field)
Ckt 1
Ckt 1
Ckt 1
20
10
12
30
10
10
50
6
10
60
6
10
30
10
10
30
10
10
50
6
10
60
6
10
40
8
10
40
8
10
50
6
10
60
6
10
90
4
8
40
8
10
40
8
10
50
6
10
60
6
10
90
4
8
50
6
10
60
6
10
90
4
8
60
6
10
60
6
10
90
4
8
60
6
10
90
4
8
N/A
N/A
N/A