Port Signal Names

Data Signals
EIA Control Signals
Conversion to RS-232
Signal Names
3-2
To assist in wiring the SSM- Megaport board, Equinox sells a
complete set of cabling accessories. See an Equinox Ordering Guide
for more information.
The names of signals on the telco connectors of the Megaport ports
indicate the direction of the signals. They are either inbound (re-
ceived by the Megaport board) or outbound (transmitted from the
Megaport board).
The following names are used for data signals:
DATA IN indicates data received by the Megaport SS board
from the attached device (inbound).
DATA OUT indicates data transmitted from the Megaport SS
board to the attached device (outbound).
The following names are used for modem control signals:
CNTL IN indicates the control signal received by the
Megaport SS board (inbound).
CNTL OUT indicates the control signal transmitted from the
Megaport SS board (outbound).
The conversion to RS-232 from the Megaport telco pinouts and signal
names (DATA IN, DATA OUT, CNTL IN and CNTL OUT) is accom-
plished by using Equinox modular adaptors and/or RS-232 distribution
panels. The information below should assist in selecting the correct
modular adaptor for the particular application.