Patton electronics Diamond Edge 3224 Installation Manual

G.shdsl ipdslam
Table of Contents

Advertisement

Quick Links

Diamond Edge Model 3224
G.SHDSL IpDSLAM
Installation Guide
Sales Office:
+1 (301) 975-1000
Technical Support:
+1 (301) 975-1007
E-mail:
support@patton.com
WWW:
www.patton.com
Document Number: 11002U4-001 Rev. C
Part Number: 07MD3224-IG
Revised: January 13, 2010

Advertisement

Table of Contents
loading

Summary of Contents for Patton electronics Diamond Edge 3224

  • Page 1 Diamond Edge Model 3224 G.SHDSL IpDSLAM Installation Guide Sales Office: +1 (301) 975-1000 Technical Support: +1 (301) 975-1007 E-mail: support@patton.com WWW: www.patton.com Document Number: 11002U4-001 Rev. C Part Number: 07MD3224-IG Revised: January 13, 2010...
  • Page 2 Patton Electronics Company, Inc. 7622 Rickenbacker Drive Gaithersburg, MD 20879 USA tel: +1 (301) 975-1000 fax: +1 (301) 869-9293 support: +1 (301) 975-1007 web: www.patton.com e-mail: support@patton.com Copyright © 2003-2010, Patton Electronics Company. All rights reserved. The information in this document is subject to change without notice. Patton Electronics assumes no liability for errors that may appear in this document.
  • Page 3: Table Of Contents

    Contents About this guide ..............................5 Audience................................. 5 Structure................................. 5 Precautions ................................6 Typographical conventions used in this document....................6 General conventions ............................6 Mouse conventions ............................7 Compliance Information ............................9 Radio and TV Interference ............................. 9 FCC Part 68 (ACTA) Statement ..........................9 Industry Canada Notice ............................9 1 Introduction ..............................
  • Page 4 Contents Model 3224 G.SHDSL IpDSLAM Installation Guide Connecting the EIA-561 RS-232 configuration port (DCE configured) ............26 Connecting the DSL Ports ..........................26 Completing the hardware installation ........................27 AC Units ................................27 DC Units ................................27 3 Configuring the IpDSLAM for operation ..................... 29 Introduction ................................30 Configuration prerequisites ...........................30 Preparing the IpDSLAM for configuration......................30...
  • Page 5: About This Guide

    About this guide This guide describes installing and configuring a Patton Electronics Model 3224 IpDSLAM. By the time you are finished with this guide, your IpDSLAM will be installed. The instructions in this guide are based on the following assumptions: •...
  • Page 6: Precautions

    About this guide Model 3224 G.SHDSL IpDSLAM Installation Guide Precautions Notes and cautions, which have the following meanings, are used throughout this guide to help you become aware of potential IpDSLAM problems: Note Calls attention to important information. The shock hazard symbol and WARNING heading indicate a potential electric shock hazard.
  • Page 7: Mouse Conventions

    Model 3224 G.SHDSL IpDSLAM Installation Guide About this guide Mouse conventions The following conventions are used when describing mouse actions: Table 2. Mouse conventions Convention Meaning Left mouse button This button refers to the primary or leftmost mouse button (unless you have changed the default configuration).
  • Page 8 About this guide Model 3224 G.SHDSL IpDSLAM Installation Guide...
  • Page 9: Compliance Information

    Compliance Information Radio and TV Interference The Model 3224 generates and uses radio frequency energy, and if not installed and used properly—that is, in strict accordance with the manufacturer's instructions—may cause interference to radio and television recep- tion. The Model 3224 has been tested and found to comply with the limits for a Class A computing device in accordance with the specifications in Subpart B of Part 15 of FCC rules, which are designed to provide reason- able protection from such interference in a commercial installation.
  • Page 10 Compliance Information Model 3224 G.SHDSL IpDSLAM Installation Guide the user's satisfaction. Before installing this equipment, users should ensure that it is permissible to be con- nected to the facilities of the local telecommunications company. The equipment must also be installed using an acceptable method of connection.
  • Page 11: Introduction

    Chapter 1 Introduction Chapter contents Model 3224 IpDSLAM overview ..........................12 Hardware overview ..............................13 ................................13 RS-232 control port ............................13 Power system ..............................14 Central processing unit ...........................14 G.SHDSL ports ..............................14 Alarm port ..............................14 Temperature ..............................15 Altitude ................................15 Humidity ................................15 Physical dimensions ............................15 Management services ............................16 LED Display...
  • Page 12: Model 3224 Ipdslam Overview

    1 • Introduction Model 3224 G.SHDSL IpDSLAM Installation Guide Model 3224 IpDSLAM overview The Model 3224 (see figure 1) connects up to 24 G.SHDSL devices to multiple WAN and Ethernet uplink ports with completely flexible routing and packet filtering. The IpDSLAM combines dual-redundant, remov- able power supplies, an IP firewall, a router, and a centralized management system into an ultra-sleek 1U chas- sis.
  • Page 13: Hardware Overview

    Model 3224 G.SHDSL IpDSLAM Installation Guide 1 • Introduction Hardware overview The Model 3224 combines transmission and routing technology, concentrating 24 G.SHDSL ports and a flex- ible selection of WAN links into a 1U-high managed chassis. The IpDSLAM (see figure 2) comprises a 1U- high, 19-inch wide chassis containing a motherboard and two dual-redundant power supplies.
  • Page 14: Power System

    1 • Introduction Model 3224 G.SHDSL IpDSLAM Installation Guide • Hardware CD and DTR signals for external modems Power system Power consumption is less than 135 watts Removable internal dual-redundant AC or DC, load-sharing power supplies The Model 3224 can only be configured with two AC power supplies or two DC supplies, you cannot mix AC and DC sup- plies in the same chassis.
  • Page 15: Temperature

      Model 3224 G.SHDSL IpDSLAM Installation Guide 1 • Introduction • 3-pin terminal block connector • 3-contact dry relay for external alarm systems Temperature Operating range: 32 to 104°F (0 to +40°C) Altitude Maximum operating altitude: 15,000 feet (4,752 meters) Humidity 5 to 90% relative humidity (RH), non-condensing Physical dimensions...
  • Page 16: Management Services

    1 • Introduction Model 3224 G.SHDSL IpDSLAM Installation Guide Management services • Out-of-Band RS-232 configuration port for management and control • SNMP version 1 MIB II configuration management • TELNET/SSH • SYSLOG Client • Remote Software Upgrade via FTP/TFTP • Built-in HTTP/HTTP server for complete configuration and control using a standard Web browser Figure 4.
  • Page 17: Approvals

    Model 3224 G.SHDSL IpDSLAM Installation Guide 1 • Introduction • ETHERNET A: Green if Ethernet link status is normal. Off if port is not configured or connected. Blink- ing indicates activity. • ETHERNET B: Green if Ethernet link status is normal. Off if port is not configured or connected. Blink- ing indicates activity.
  • Page 18 1 • Introduction Model 3224 G.SHDSL IpDSLAM Installation Guide Power Considerations...
  • Page 19: Hardware Installation

    Chapter 2 Hardware installation Chapter contents Introduction ................................20 Unpacking the Model 3224 IpDSLAM.........................20 IpDSLAM chassis installation..........................20 Cable installation..............................21 Attaching the cable retainer clip ........................21 Grounding the Model 3224—AC and DC Power Supplies ................21 Installing the power cables—AC power supply ....................22 Installing the power cables—DC Power Supply ....................24 Connecting the Ethernet ports...
  • Page 20: Introduction

    2 • Hardware installation Model 3224 G.SHDSL IpDSLAM Installation Guide Introduction This chapter contains the following procedures for installing the Model 3224 IpDSLAM: Note Before installing the IpDSLAM, you will need to obtain the line type and encoding of any WAN uplink port from your local telephone company (telco).
  • Page 21: Cable Installation

    Model 3224 G.SHDSL IpDSLAM Installation Guide 2 • Hardware installation 3. Install the rack mounting ears onto the IpDSLAM using the mounting hardware provided. 4. Place the IpDSLAM at the desired position in the rack. 5. Secure the IpDSLAM in position with the mounting screws. Cable installation This section describes installing the power, ground, and network interface cables.
  • Page 22: Installing The Power Cables-Ac Power Supply

    2 • Hardware installation Model 3224 G.SHDSL IpDSLAM Installation Guide Power cable retainer clip IEC-320 connector (2 places) Grounding stud Figure 6. IEC-320 connector and grounding stud locations Installing the power cables—AC power supply This section describes installing the female end of the power cables into the IEC-320 connectors on the IpDSLAM.
  • Page 23 Model 3224 G.SHDSL IpDSLAM Installation Guide 2 • Hardware installation Do the following: 1. Connect the earth ground of the AC source to the grounding stud on the IpDSLAM as described in the section “Grounding the Model 3224—AC and DC Power Supplies” on page 21.
  • Page 24: Installing The Power Cables-Dc Power Supply

    2 • Hardware installation Model 3224 G.SHDSL IpDSLAM Installation Guide Installing the power cables—DC Power Supply This section describes installing the DC power cables to the DC power terminal blocks on the IpDSLAM. Do not connect the remaining end of the power cables to the DC power source at this time. The Model 3224 can only be configured with two AC power supplies or two DC supplies, you cannot mix AC and DC sup- plies in the same chassis.
  • Page 25: Connecting The Ethernet Ports

    Model 3224 G.SHDSL IpDSLAM Installation Guide 2 • Hardware installation Connecting the Ethernet ports The IpDSLAM has two 10/100 Ethernet interfaces for connection to your LAN (see figure 9). The Ethernet port will autosense the correct speed of the local LAN and automatically negotiate half- or full-duplex opera- tion.
  • Page 26: Connecting A 10/100Base-T Ethernet Port To An Ethernet-Capable Workstation

    2 • Hardware installation Model 3224 G.SHDSL IpDSLAM Installation Guide Connecting a 10/100Base-T Ethernet port to an Ethernet-capable workstation The 10/100Base-T Ethernet ports can connect to a single Ethernet-capable workstation or PC by means of a cross-over cable. Refer to figure 11 to assemble a cross-connect cable that will connect between the NIC Ether- net port in the workstation and one of the IpDSLAM 10/100Base-T Ethernet ports.
  • Page 27: Completing The Hardware Installation

    Model 3224 G.SHDSL IpDSLAM Installation Guide 2 • Hardware installation 3. Select and attach the appropriate twisted pair from each remote (CPE) G.SHDSL modem on punch-down blocks for connection to the chosen G.SHDSL port in the 3224. Completing the hardware installation This section verifies that the IpDSLAM hardware is operational to the point where you can begin configuring the software settings.
  • Page 28 2 • Hardware installation Model 3224 G.SHDSL IpDSLAM Installation Guide Completing the hardware installation...
  • Page 29: Configuring The Ipdslam For Operation

    Chapter 3 Configuring the IpDSLAM for operation Chapter contents Introduction ................................30 Configuration prerequisites ...........................30 Preparing the IpDSLAM for configuration......................30 IP address quick start modification ........................32 Web operation and configuration ..........................34 PC configuration ............................34 Displaying the 3224 web administration pages ....................34...
  • Page 30: Introduction

    3 • Configuring the IpDSLAM for operation Model 3224 G.SHDSL IpDSLAM Installation Guide Introduction This chapter contains the following procedures for configuring the Model 3224 IpDSLAM for operation: • “Configuration prerequisites”—lists the items you need to have on hand before configuring the IpDSLAM. •...
  • Page 31 Model 3224 G.SHDSL IpDSLAM Installation Guide 3 • Configuring the IpDSLAM for operation 3. Set up the terminal emulation program as follows: – Open a terminal emulation session. – Enter a name for this connection. – Click on the Connect using: pop-up menu and choose the Direct to ComX option (where X is the number of the COM port onto which you connected the cable in step 1) (see figure Figure 13.
  • Page 32: Ip Address Quick Start Modification

    3 • Configuring the IpDSLAM for operation Model 3224 G.SHDSL IpDSLAM Installation Guide Figure 15. Terminal keys configuration – Configure the Settings for Function, arrow and ctrl keys act as to Terminal keys as shown in figure IP address quick start modification At turn on, boot up information will display on your Hyperterminal connection window, followed by a login request window.
  • Page 33 Model 3224 G.SHDSL IpDSLAM Installation Guide 3 • Configuring the IpDSLAM for operation 2. To change the 3224’s Ethernet A default IP address of 192.168.200.1/24 to your selected IP address, select option N, then press <enter>. The 3224 will display IP address and netmask for Ethernet interfaces. 3.
  • Page 34: Web Operation And Configuration

    3 • Configuring the IpDSLAM for operation Model 3224 G.SHDSL IpDSLAM Installation Guide Web operation and configuration Now that the IP address has been configured for your application, you can complete the configuration using any standard web browser. PC configuration Note To connect the PC to the Ethernet LAN to communicate with the Model 3224, the PC’s IP address should be on the same subnet as the...
  • Page 35 Model 3224 G.SHDSL IpDSLAM Installation Guide 3 • Configuring the IpDSLAM for operation 5. The Model 3224 Configuration Menu home page will appear (see figure 16). Figure 16. Model 3224 Configuration Menu home page Web operation and configuration...
  • Page 36 3 • Configuring the IpDSLAM for operation Model 3224 G.SHDSL IpDSLAM Installation Guide Figure 17. Home Page window panes The HOME window is divided into two panes: the Configuration Menu pane and the Configuration/infor- mation pane (see figure 17). The Configuration Menu contains the links to the various Model 3224 sub- systems, while in the Configuration/information pane;...
  • Page 37 Model 3224 G.SHDSL IpDSLAM Installation Guide 3 • Configuring the IpDSLAM for operation Figure 18. Immediate Actions buttons From the Home page, the following actions can be performed: • Record Current Configuration—clicking on this button (see figure 18) saves the current configuration in volatile DRAM memory to FLASH memory.
  • Page 38 3 • Configuring the IpDSLAM for operation Model 3224 G.SHDSL IpDSLAM Installation Guide Web operation and configuration...
  • Page 39: Operation And Shutdown

    Chapter 4 Operation and shutdown Chapter contents Introduction ................................40 Activating the IpDSLAM ............................40 De-activating the IpDSLAM ..........................40...
  • Page 40: Introduction

    4 • Operation and shutdown Model 3224 G.SHDSL IpDSLAM Installation Guide Introduction This chapter describes how to start or power-down the IpDSLAM. Activating the IpDSLAM Once the IpDSLAM has been installed, no operator action is required under normal conditions; the IpDSLAM is designed for unattended operation.
  • Page 41: Maintenance

    Chapter 5 Maintenance Chapter contents Introduction ................................42 Replacing a power supply ............................42...
  • Page 42: Introduction

    5 • Maintenance Model 3224 G.SHDSL IpDSLAM Installation Guide Introduction This chapter describes replacing a Model 3224 power supply. If you require more help, refer to chapter 6, “Contacting Patton for assistance” on page 45. Replacing a power supply Model 3224 IpDSLAM power supplies are hot-swappable, so a defective supply can be replaced without deac- tivating the IpDSLAM.
  • Page 43 Model 3224 G.SHDSL IpDSLAM Installation Guide 5 • Maintenance 3. Using a flat-tip screwdriver, loosen the two captive fasteners (see figure 19) enough so they are no longer connecting the power supply to the IpDSLAM chassis. 4. Carefully, pull the power supply from the IpDSLAM chassis until it is completely removed. Do not use the power cable retainer clip as a handle when remov- ing the power supply from the IpDSLAM chassis.
  • Page 44 5 • Maintenance Model 3224 G.SHDSL IpDSLAM Installation Guide 11. Place the defective power supply into the shipping container that was used to transport the replacement power supply. 12. Depending on the instructions you received when you obtained your RMA number, return the defective power supply to your distributor or to Patton Electronics.
  • Page 45: Contacting Patton For Assistance

    Chapter 6 Contacting Patton for assistance Chapter contents Introduction ................................46 Contact information..............................46 Warranty Service and Returned Merchandise Authorizations (RMAs)..............46 Warranty coverage ............................46 Out-of-warranty service ..........................46 Returns for credit ............................46 Return for credit policy ..........................47 RMA numbers ..............................47 Shipping instructions ..........................47...
  • Page 46: Introduction

    6 • Contacting Patton for assistance Model 3224 G.SHDSL IpDSLAM Installation Guide Introduction This chapter contains the following information: • “Contact information”—describes how to contact PATTON technical support for assistance. • “Warranty Service and Returned Merchandise Authorizations (RMAs)”—contains information about the RAS warranty and obtaining a return merchandise authorization (RMA).
  • Page 47: Return For Credit Policy

    Model 3224 G.SHDSL IpDSLAM Installation Guide 6 • Contacting Patton for assistance Return for credit policy • Less than 30 days: No Charge. Your credit will be issued upon receipt and inspection of the equipment. • 30 to 60 days: We will add a 20% restocking charge (crediting your account with 80% of the purchase price).
  • Page 48 6 • Contacting Patton for assistance Model 3224 G.SHDSL IpDSLAM Installation Guide Warranty Service and Returned Merchandise Authorizations (RMAs)
  • Page 49: A Network Ports (Rj-21X) Connector Pin-Out

    Appendix A Network Ports (RJ-21X) connector pin-out Chapter contents Introduction ................................50...
  • Page 50: Introduction

    Model 3224 G.SHDSL IpDSLAM Installation Guide A • Network Ports (RJ-21X) connector pin-out Introduction Table 3 contains the band-marked color codes for the RJ-21X, 50-pin Telco connector. The Pair Number matches the port number on the DS0 Mapping Management page. NETWORK PORTS Figure 21.
  • Page 51 Model 3224 G.SHDSL IpDSLAM Installation Guide A • Network Ports (RJ-21X) connector pin-out Table 3. Band Marked Color Code (Continued) Wire/Color Code Tip and Ring Pair Number 50 Pin Positions Black/Slate Tip 15 Pair 15 Slate/Black Ring 15 Yellow/Blue Tip 16 Pair 16 Blue/Yellow Ring 16...
  • Page 52 Model 3224 G.SHDSL IpDSLAM Installation Guide A • Network Ports (RJ-21X) connector pin-out Introduction...

Table of Contents